A comparison of cardiac index in normal term pregnancy using thoracic electrical bio-impedance and oxygen extraction (Fick) techniques

S. L. Clark, J. Southwick, J. M. Pivarnik, D. B. Cotton, Gary Hankins, J. P. Phelan

Research output: Contribution to journalArticle

37 Citations (Scopus)

Abstract

Objective: To correlate cardiac index in normal late third-trimester pregnancy using the thoracic electrical bio-impedance technique with that obtained from the oxygen extraction technique. Methods: Eight carefully screened normal pregnant women underwent assessment of cardiac index using both the thoracic electrical bio-impedance technique and the oxygen extraction technique. Measurements were obtained in various positions. Results: The correlation was good between the thoracic electrical bio-impedance and oxygen extraction techniques in the left lateral (r = 0.915) and right lateral (r = 0.863) positions, and the intercepts at the midpoints of the oxygen extraction data in these positions suggested good absolute correlation as well. Correlation between thoracic electrical bio-impedance and the Fick cardiac index was poor in all other positions. Conclusions: Thoracic electrical bio-impedance cardiac index assessment is influenced by maternal position and must be used with caution in clinical research protocols. This technique appears to be inappropriate for general clinical use during pregnancy.

Original languageEnglish (US)
Pages (from-to)669-672
Number of pages4
JournalObstetrics and Gynecology
Volume83
Issue number5 I
StatePublished - 1994
Externally publishedYes

Fingerprint

Electric Impedance
Thorax
Oxygen
Pregnancy
Third Pregnancy Trimester
Clinical Protocols
Pregnant Women
Mothers

ASJC Scopus subject areas

  • Obstetrics and Gynecology

Cite this

Clark, S. L., Southwick, J., Pivarnik, J. M., Cotton, D. B., Hankins, G., & Phelan, J. P. (1994). A comparison of cardiac index in normal term pregnancy using thoracic electrical bio-impedance and oxygen extraction (Fick) techniques. Obstetrics and Gynecology, 83(5 I), 669-672.

A comparison of cardiac index in normal term pregnancy using thoracic electrical bio-impedance and oxygen extraction (Fick) techniques. / Clark, S. L.; Southwick, J.; Pivarnik, J. M.; Cotton, D. B.; Hankins, Gary; Phelan, J. P.

In: Obstetrics and Gynecology, Vol. 83, No. 5 I, 1994, p. 669-672.

Research output: Contribution to journalArticle

Clark, SL, Southwick, J, Pivarnik, JM, Cotton, DB, Hankins, G & Phelan, JP 1994, 'A comparison of cardiac index in normal term pregnancy using thoracic electrical bio-impedance and oxygen extraction (Fick) techniques', Obstetrics and Gynecology, vol. 83, no. 5 I, pp. 669-672.
Clark, S. L. ; Southwick, J. ; Pivarnik, J. M. ; Cotton, D. B. ; Hankins, Gary ; Phelan, J. P. / A comparison of cardiac index in normal term pregnancy using thoracic electrical bio-impedance and oxygen extraction (Fick) techniques. In: Obstetrics and Gynecology. 1994 ; Vol. 83, No. 5 I. pp. 669-672.
@article{a9be45e4b8a34f1cb73f710f5ff6932f,
title = "A comparison of cardiac index in normal term pregnancy using thoracic electrical bio-impedance and oxygen extraction (Fick) techniques",
abstract = "Objective: To correlate cardiac index in normal late third-trimester pregnancy using the thoracic electrical bio-impedance technique with that obtained from the oxygen extraction technique. Methods: Eight carefully screened normal pregnant women underwent assessment of cardiac index using both the thoracic electrical bio-impedance technique and the oxygen extraction technique. Measurements were obtained in various positions. Results: The correlation was good between the thoracic electrical bio-impedance and oxygen extraction techniques in the left lateral (r = 0.915) and right lateral (r = 0.863) positions, and the intercepts at the midpoints of the oxygen extraction data in these positions suggested good absolute correlation as well. Correlation between thoracic electrical bio-impedance and the Fick cardiac index was poor in all other positions. Conclusions: Thoracic electrical bio-impedance cardiac index assessment is influenced by maternal position and must be used with caution in clinical research protocols. This technique appears to be inappropriate for general clinical use during pregnancy.",
author = "Clark, {S. L.} and J. Southwick and Pivarnik, {J. M.} and Cotton, {D. B.} and Gary Hankins and Phelan, {J. P.}",
year = "1994",
language = "English (US)",
volume = "83",
pages = "669--672",
journal = "Obstetrics and Gynecology",
issn = "0029-7844",
publisher = "Lippincott Williams and Wilkins",
number = "5 I",

}

TY - JOUR

T1 - A comparison of cardiac index in normal term pregnancy using thoracic electrical bio-impedance and oxygen extraction (Fick) techniques

AU - Clark, S. L.

AU - Southwick, J.

AU - Pivarnik, J. M.

AU - Cotton, D. B.

AU - Hankins, Gary

AU - Phelan, J. P.

PY - 1994

Y1 - 1994

N2 - Objective: To correlate cardiac index in normal late third-trimester pregnancy using the thoracic electrical bio-impedance technique with that obtained from the oxygen extraction technique. Methods: Eight carefully screened normal pregnant women underwent assessment of cardiac index using both the thoracic electrical bio-impedance technique and the oxygen extraction technique. Measurements were obtained in various positions. Results: The correlation was good between the thoracic electrical bio-impedance and oxygen extraction techniques in the left lateral (r = 0.915) and right lateral (r = 0.863) positions, and the intercepts at the midpoints of the oxygen extraction data in these positions suggested good absolute correlation as well. Correlation between thoracic electrical bio-impedance and the Fick cardiac index was poor in all other positions. Conclusions: Thoracic electrical bio-impedance cardiac index assessment is influenced by maternal position and must be used with caution in clinical research protocols. This technique appears to be inappropriate for general clinical use during pregnancy.

AB - Objective: To correlate cardiac index in normal late third-trimester pregnancy using the thoracic electrical bio-impedance technique with that obtained from the oxygen extraction technique. Methods: Eight carefully screened normal pregnant women underwent assessment of cardiac index using both the thoracic electrical bio-impedance technique and the oxygen extraction technique. Measurements were obtained in various positions. Results: The correlation was good between the thoracic electrical bio-impedance and oxygen extraction techniques in the left lateral (r = 0.915) and right lateral (r = 0.863) positions, and the intercepts at the midpoints of the oxygen extraction data in these positions suggested good absolute correlation as well. Correlation between thoracic electrical bio-impedance and the Fick cardiac index was poor in all other positions. Conclusions: Thoracic electrical bio-impedance cardiac index assessment is influenced by maternal position and must be used with caution in clinical research protocols. This technique appears to be inappropriate for general clinical use during pregnancy.

UR - http://www.scopus.com/inward/record.url?scp=0028318799&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028318799&partnerID=8YFLogxK

M3 - Article

C2 - 8164923

AN - SCOPUS:0028318799

VL - 83

SP - 669

EP - 672

JO - Obstetrics and Gynecology

JF - Obstetrics and Gynecology

SN - 0029-7844

IS - 5 I

ER -