A non-invasive in vivo imaging system to study dissemination of bioluminescent Yersinia pestis CO92 in a mouse model of pneumonic plague

Jian Sha, Jason A. Rosenzweig, Michelle L. Kirtley, Christina J. van Lier, Eric C. Fitts, Elena V. Kozlova, Tatiana E. Erova, Bethany L. Tiner, Ashok K. Chopra

Research output: Contribution to journalArticlepeer-review

26 Scopus citations

Abstract

The gold standard in microbiology for monitoring bacterial dissemination in infected animals has always been viable plate counts. This method, despite being quantitative, requires sacrificing the infected animals. Recently, however, an alternative method of in vivo imaging of bioluminescent bacteria (IVIBB) for monitoring microbial dissemination within the host has been employed. Yersinia pestis is a Gram-negative bacterium capable of causing bubonic, septicemic, and pneumonic plague. In this study, we compared the conventional counting of bacterial colony forming units (cfu) in the various infected tissues to IVIBB in monitoring Y. pestis dissemination in a mouse model of pneumonic plague. By using a transposon mutagenesis system harboring the luciferase (luc) gene, we screened approximately 4000 clones and obtained a fully virulent, luc-positive Y. pestis CO92 (Y. pestis-luc2) reporter strain in which transposition occurred within the largest pMT1 plasmid which possesses murine toxin and capsular antigen encoding genes. The aforementioned reporter strain and the wild-type CO92 exhibited similar growth curves, formed capsule based on immunofluorescence microscopy and flow cytometry, and had a similar LD50. Intranasal infection of mice with 15 LD50 of CO92-luc2 resulted in animal mortality by 72 h, and an increasing number of bioluminescent bacteria were observed in various mouse organs over a 24-72 h period when whole animals were imaged. However, following levofloxacin treatment (10 mg/kg/day) for 6 days 24 h post infection, no luminescence was observed after 72 h of infection, indicating that the tested antimicrobial killed bacteria preventing their detection in host peripheral tissues. Overall, we demonstrated that IVIBB is an effective and non-invasive way of monitoring bacterial dissemination in animals following pneumonic plague having strong correlation with cfu, and our reporter CO92-luc2 strain can be employed as a useful tool to monitor the efficacy of antimicrobial countermeasures in real time.

Original languageEnglish (US)
Pages (from-to)39-50
Number of pages12
JournalMicrobial Pathogenesis
Volume55
Issue number1
DOIs
StatePublished - Feb 2013

Keywords

  • Bacterial dissemination
  • Bioluminescent Yersinia pestis
  • Flow cytometry
  • Immunofluorescence microscopy
  • In vivo imaging
  • Levofloxacin
  • Pneumonic plague

ASJC Scopus subject areas

  • Microbiology
  • Infectious Diseases

Fingerprint

Dive into the research topics of 'A non-invasive in vivo imaging system to study dissemination of bioluminescent Yersinia pestis CO92 in a mouse model of pneumonic plague'. Together they form a unique fingerprint.

Cite this