Skip to main navigation Skip to search Skip to main content

AARC Clinical Practice Guideline: Patient-Ventilator Assessment

  • Lynda T. Goodfellow
  • , Andrew G. Miller
  • , Sarah M. Varekojis
  • , Carolyn J. Lavita
  • , Joel T. Glogowski
  • , Dean R. Hess

Research output: Contribution to journal › Article › peer-review

Abstract

Given the important role of patient-ventilator assessments in ensuring the safety and efficacy of mechanical ventilation, a team of respiratory therapists and a librarian used Grading of Recommendations, Assessment, Development, and Evaluation methodology to make the following recommendations: (1) We recommend assessment of plateau pressure to ensure lung-protective ventilator settings (strong recommendation, high certainty); (2) We recommend an assessment of tidal volume (VT) to ensure lung-protective ventilation (4–8 mL/kg/predicted body weight) (strong recommendation, high certainty); (3) We recommend documenting VT as mL/kg predicted body weight (strong recommendation, high certainty); (4) We recommend an assessment of PEEP and auto-PEEP (strong recommendation, high certainty); (5) We suggest assessing driving pressure to prevent ventilator-induced injury (conditional recommendation, low certainty); (6) We suggest assessing FIO2 to ensure normoxemia (conditional recommendation, very low certainty); (7) We suggest telemonitoring to supplement direct bedside assessment in settings with limited resources (conditional recommendation, low certainty); (8) We suggest direct bedside assessment rather than telemonitoring when resources are adequate (conditional recommendation, low certainty); (9) We suggest assessing adequate humidification for patients receiving noninvasive ventilation (NIV) and invasive mechanical ventilation (conditional recommendation, very low certainty); (10) We suggest assessing the appropriateness of the humidification device during NIV and invasive mechanical ventilation (conditional recommendation, low certainty); (11) We recommend that the skin surrounding artificial airways and NIV interfaces be assessed (strong recommendation, high certainty); (12) We suggest assessing the dressing used for tracheostomy tubes and NIV interfaces (conditional recommendation, low certainty); (13) We recommend assessing the pressure inside the cuff of artificial airways using a manometer (strong recommendation, high certainty); (14) We recommend that continuous cuff pressure assessment should not be implemented to decrease the risk of ventilator-associated pneumonia (strong recommendation, high certainty); and (15) We suggest assessing the proper placement and securement of artificial airways (conditional recommendation, very low certainty).

Original languageEnglish (US)
Pages (from-to)1042-1054
Number of pages13
JournalRespiratory care
Volume69
Issue number8
DOIs
StatePublished - Aug 1 2024
Externally publishedYes

Keywords

  • Adjustments
  • Auscultation
  • Dyspnea
  • Evidence-Based Respiratory Care
  • Guidelines
  • Mechanical Ventilation
  • Patient assessment
  • Patient distress
  • Physical examination
  • Safety
  • Stability
  • Trends

ASJC Scopus subject areas

  • Pulmonary and Respiratory Medicine
  • Critical Care and Intensive Care Medicine

Fingerprint

Dive into the research topics of 'AARC Clinical Practice Guideline: Patient-Ventilator Assessment'. Together they form a unique fingerprint.

Cite this