Amniotic fluid index measured with the aid of color flow Doppler

M. G. Zlatnik, Gayle Olson, R. Bukowski, George Saade

Research output: Contribution to journalArticle

9 Citations (Scopus)

Abstract

Objective: To determine whether using color flow Doppler to identify the umbilical cord affects amniotic fluid index (AFI) measurements. Methods: A total of 2236 AFI measurements between 24 and 42 weeks in singleton gestations with no known or suspected fetal anomalies and < 14 days' discrepancy between menstrual and ultrasonographic dating were included. Color flow Doppler was used to identify loops of umbilical cord; these were excluded from the measurement. Polynomial regression was used to generate means and centiles. Data were grouped according to completed weeks of gestation and descriptive statistics were calculated. At each week of gestation, the number and percentage of pregnancies diagnosed as ≤ 2.5th, ≤ 5th, ≥ 95th, and ≥ 97.5th centile according to a 'standard' nomogram derived without using color flow Doppler were calculated. Results: The AFI decreased significantly over gestational age, starting at 31 weeks (p < 0.05 by ANOVA). The relationship between AFI and gestational age was best modeled by a second-degree polynomial (p < 0.001). The median and range of the proportion of AFIs that fell outside the ranges of the standard nomogram at each completed gestational age was: 6.0 (2.3-35.4)% for the ≤ 2.5th centile, 9.9 (3.1-37.5)% for the ≤ 5th centile, 3.8 (0-30)% for the ≥ 95th centile, and 1.8 (0-20)% for the ≥ 97.5th centile. The 2.5th and 5th centiles using the current data were lower than those of the 'standard', and the difference increased with advancing gestation. Upper centiles were also different. Conclusion: The AFI measured using color flow Doppler overestimates oligohydramnios and may underestimate polyhydramnios when a standard AFI table obtained without color flow Doppler is used. Normal values specific for measurement method should be used for reference.

Original languageEnglish
Pages (from-to)242-245
Number of pages4
JournalJournal of Maternal-Fetal and Neonatal Medicine
Volume13
Issue number4
StatePublished - Apr 1 2003

Fingerprint

Amniotic Fluid
Color
Pregnancy
Gestational Age
Nomograms
Umbilical Cord
Oligohydramnios
Polyhydramnios
Analysis of Variance
Reference Values

Keywords

  • Amniotic fluid index
  • Color Doppler
  • Oligohydramnios
  • Ultrasonography

ASJC Scopus subject areas

  • Pediatrics, Perinatology, and Child Health
  • Obstetrics and Gynecology

Cite this

Amniotic fluid index measured with the aid of color flow Doppler. / Zlatnik, M. G.; Olson, Gayle; Bukowski, R.; Saade, George.

In: Journal of Maternal-Fetal and Neonatal Medicine, Vol. 13, No. 4, 01.04.2003, p. 242-245.

Research output: Contribution to journalArticle

@article{4946a370ce4d413da3eafce825bd06ab,
title = "Amniotic fluid index measured with the aid of color flow Doppler",
abstract = "Objective: To determine whether using color flow Doppler to identify the umbilical cord affects amniotic fluid index (AFI) measurements. Methods: A total of 2236 AFI measurements between 24 and 42 weeks in singleton gestations with no known or suspected fetal anomalies and < 14 days' discrepancy between menstrual and ultrasonographic dating were included. Color flow Doppler was used to identify loops of umbilical cord; these were excluded from the measurement. Polynomial regression was used to generate means and centiles. Data were grouped according to completed weeks of gestation and descriptive statistics were calculated. At each week of gestation, the number and percentage of pregnancies diagnosed as ≤ 2.5th, ≤ 5th, ≥ 95th, and ≥ 97.5th centile according to a 'standard' nomogram derived without using color flow Doppler were calculated. Results: The AFI decreased significantly over gestational age, starting at 31 weeks (p < 0.05 by ANOVA). The relationship between AFI and gestational age was best modeled by a second-degree polynomial (p < 0.001). The median and range of the proportion of AFIs that fell outside the ranges of the standard nomogram at each completed gestational age was: 6.0 (2.3-35.4){\%} for the ≤ 2.5th centile, 9.9 (3.1-37.5){\%} for the ≤ 5th centile, 3.8 (0-30){\%} for the ≥ 95th centile, and 1.8 (0-20){\%} for the ≥ 97.5th centile. The 2.5th and 5th centiles using the current data were lower than those of the 'standard', and the difference increased with advancing gestation. Upper centiles were also different. Conclusion: The AFI measured using color flow Doppler overestimates oligohydramnios and may underestimate polyhydramnios when a standard AFI table obtained without color flow Doppler is used. Normal values specific for measurement method should be used for reference.",
keywords = "Amniotic fluid index, Color Doppler, Oligohydramnios, Ultrasonography",
author = "Zlatnik, {M. G.} and Gayle Olson and R. Bukowski and George Saade",
year = "2003",
month = "4",
day = "1",
language = "English",
volume = "13",
pages = "242--245",
journal = "Journal of Maternal-Fetal and Neonatal Medicine",
issn = "1476-7058",
publisher = "Informa Healthcare",
number = "4",

}

TY - JOUR

T1 - Amniotic fluid index measured with the aid of color flow Doppler

AU - Zlatnik, M. G.

AU - Olson, Gayle

AU - Bukowski, R.

AU - Saade, George

PY - 2003/4/1

Y1 - 2003/4/1

N2 - Objective: To determine whether using color flow Doppler to identify the umbilical cord affects amniotic fluid index (AFI) measurements. Methods: A total of 2236 AFI measurements between 24 and 42 weeks in singleton gestations with no known or suspected fetal anomalies and < 14 days' discrepancy between menstrual and ultrasonographic dating were included. Color flow Doppler was used to identify loops of umbilical cord; these were excluded from the measurement. Polynomial regression was used to generate means and centiles. Data were grouped according to completed weeks of gestation and descriptive statistics were calculated. At each week of gestation, the number and percentage of pregnancies diagnosed as ≤ 2.5th, ≤ 5th, ≥ 95th, and ≥ 97.5th centile according to a 'standard' nomogram derived without using color flow Doppler were calculated. Results: The AFI decreased significantly over gestational age, starting at 31 weeks (p < 0.05 by ANOVA). The relationship between AFI and gestational age was best modeled by a second-degree polynomial (p < 0.001). The median and range of the proportion of AFIs that fell outside the ranges of the standard nomogram at each completed gestational age was: 6.0 (2.3-35.4)% for the ≤ 2.5th centile, 9.9 (3.1-37.5)% for the ≤ 5th centile, 3.8 (0-30)% for the ≥ 95th centile, and 1.8 (0-20)% for the ≥ 97.5th centile. The 2.5th and 5th centiles using the current data were lower than those of the 'standard', and the difference increased with advancing gestation. Upper centiles were also different. Conclusion: The AFI measured using color flow Doppler overestimates oligohydramnios and may underestimate polyhydramnios when a standard AFI table obtained without color flow Doppler is used. Normal values specific for measurement method should be used for reference.

AB - Objective: To determine whether using color flow Doppler to identify the umbilical cord affects amniotic fluid index (AFI) measurements. Methods: A total of 2236 AFI measurements between 24 and 42 weeks in singleton gestations with no known or suspected fetal anomalies and < 14 days' discrepancy between menstrual and ultrasonographic dating were included. Color flow Doppler was used to identify loops of umbilical cord; these were excluded from the measurement. Polynomial regression was used to generate means and centiles. Data were grouped according to completed weeks of gestation and descriptive statistics were calculated. At each week of gestation, the number and percentage of pregnancies diagnosed as ≤ 2.5th, ≤ 5th, ≥ 95th, and ≥ 97.5th centile according to a 'standard' nomogram derived without using color flow Doppler were calculated. Results: The AFI decreased significantly over gestational age, starting at 31 weeks (p < 0.05 by ANOVA). The relationship between AFI and gestational age was best modeled by a second-degree polynomial (p < 0.001). The median and range of the proportion of AFIs that fell outside the ranges of the standard nomogram at each completed gestational age was: 6.0 (2.3-35.4)% for the ≤ 2.5th centile, 9.9 (3.1-37.5)% for the ≤ 5th centile, 3.8 (0-30)% for the ≥ 95th centile, and 1.8 (0-20)% for the ≥ 97.5th centile. The 2.5th and 5th centiles using the current data were lower than those of the 'standard', and the difference increased with advancing gestation. Upper centiles were also different. Conclusion: The AFI measured using color flow Doppler overestimates oligohydramnios and may underestimate polyhydramnios when a standard AFI table obtained without color flow Doppler is used. Normal values specific for measurement method should be used for reference.

KW - Amniotic fluid index

KW - Color Doppler

KW - Oligohydramnios

KW - Ultrasonography

UR - http://www.scopus.com/inward/record.url?scp=0037395740&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0037395740&partnerID=8YFLogxK

M3 - Article

C2 - 12854924

AN - SCOPUS:0037395740

VL - 13

SP - 242

EP - 245

JO - Journal of Maternal-Fetal and Neonatal Medicine

JF - Journal of Maternal-Fetal and Neonatal Medicine

SN - 1476-7058

IS - 4

ER -