Automatic ultrasound determination of thermal coagulation front during laser tissue heating

Zhigang Sun, Hao Ying, Jialiang Lu, Brent Bell, Daniel F. Cowan, Massoud Motamedi

Research output: Contribution to journalArticle

7 Citations (Scopus)

Abstract

Thermal therapies using laser, microwaves, radio frequency radiation, and high intensity focused ultrasound have shown great promise for minimally invasive treatment of benign and malignant lesions. To treat tissue effectively and safely, techniques that could monitor the advancement of coagulation front during treatment are highly desirable. This paper presents a noninvasive ultrasound technique for automatically determining the propagation of coagulation damage front during laser tissue heating. The basic assumption underlying this technique is that when coagulation is taking place in a tissue, owing to thermally induced structure changes in tissue, the waveform of echo signal scattered from that treated region should be changing accordingly. We first track echoes scattered from many small tissue regions during heating using a cross-correlation echo-tracking technique. We then use the waveform-change information to determine the position of coagulation front via an automatic calculation procedure. To test our technique, we carried out 35 experiments in which we irradiated fresh canine liver samples with a Nd:YAG laser (1064-nm wavelength) at various light fluence (62 to 167 W/cm2) and exposure time (20 to 350 s). A 13-mm diameter 10-MHz broadband single-element spherical focused ultrasound transducer was used to detect the thermal coagulation front. The root mean square difference between ultrasonically and visually determined coagulation depths was 0.77 mm. This good agreement between visually inspected and ultrasonically determined coagulation depths shows the potential of our technique for monitoring coagulative tissue damage during thermal therapy.

Original languageEnglish (US)
Pages (from-to)1134-1146
Number of pages13
JournalIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Volume46
Issue number5
DOIs
StatePublished - 1999

Fingerprint

coagulation
Coagulation
Ultrasonics
Tissue
Heating
heating
Lasers
lasers
echoes
therapy
waveforms
damage
radio waves
Hot Temperature
liver
Liver
lesions
cross correlation
YAG lasers
Transducers

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Acoustics and Ultrasonics

Cite this

Automatic ultrasound determination of thermal coagulation front during laser tissue heating. / Sun, Zhigang; Ying, Hao; Lu, Jialiang; Bell, Brent; Cowan, Daniel F.; Motamedi, Massoud.

In: IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, Vol. 46, No. 5, 1999, p. 1134-1146.

Research output: Contribution to journalArticle

@article{49fdb014ab354597a4bdd71e191b2cb4,
title = "Automatic ultrasound determination of thermal coagulation front during laser tissue heating",
abstract = "Thermal therapies using laser, microwaves, radio frequency radiation, and high intensity focused ultrasound have shown great promise for minimally invasive treatment of benign and malignant lesions. To treat tissue effectively and safely, techniques that could monitor the advancement of coagulation front during treatment are highly desirable. This paper presents a noninvasive ultrasound technique for automatically determining the propagation of coagulation damage front during laser tissue heating. The basic assumption underlying this technique is that when coagulation is taking place in a tissue, owing to thermally induced structure changes in tissue, the waveform of echo signal scattered from that treated region should be changing accordingly. We first track echoes scattered from many small tissue regions during heating using a cross-correlation echo-tracking technique. We then use the waveform-change information to determine the position of coagulation front via an automatic calculation procedure. To test our technique, we carried out 35 experiments in which we irradiated fresh canine liver samples with a Nd:YAG laser (1064-nm wavelength) at various light fluence (62 to 167 W/cm2) and exposure time (20 to 350 s). A 13-mm diameter 10-MHz broadband single-element spherical focused ultrasound transducer was used to detect the thermal coagulation front. The root mean square difference between ultrasonically and visually determined coagulation depths was 0.77 mm. This good agreement between visually inspected and ultrasonically determined coagulation depths shows the potential of our technique for monitoring coagulative tissue damage during thermal therapy.",
author = "Zhigang Sun and Hao Ying and Jialiang Lu and Brent Bell and Cowan, {Daniel F.} and Massoud Motamedi",
year = "1999",
doi = "10.1109/58.796119",
language = "English (US)",
volume = "46",
pages = "1134--1146",
journal = "IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control",
issn = "0885-3010",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "5",

}

TY - JOUR

T1 - Automatic ultrasound determination of thermal coagulation front during laser tissue heating

AU - Sun, Zhigang

AU - Ying, Hao

AU - Lu, Jialiang

AU - Bell, Brent

AU - Cowan, Daniel F.

AU - Motamedi, Massoud

PY - 1999

Y1 - 1999

N2 - Thermal therapies using laser, microwaves, radio frequency radiation, and high intensity focused ultrasound have shown great promise for minimally invasive treatment of benign and malignant lesions. To treat tissue effectively and safely, techniques that could monitor the advancement of coagulation front during treatment are highly desirable. This paper presents a noninvasive ultrasound technique for automatically determining the propagation of coagulation damage front during laser tissue heating. The basic assumption underlying this technique is that when coagulation is taking place in a tissue, owing to thermally induced structure changes in tissue, the waveform of echo signal scattered from that treated region should be changing accordingly. We first track echoes scattered from many small tissue regions during heating using a cross-correlation echo-tracking technique. We then use the waveform-change information to determine the position of coagulation front via an automatic calculation procedure. To test our technique, we carried out 35 experiments in which we irradiated fresh canine liver samples with a Nd:YAG laser (1064-nm wavelength) at various light fluence (62 to 167 W/cm2) and exposure time (20 to 350 s). A 13-mm diameter 10-MHz broadband single-element spherical focused ultrasound transducer was used to detect the thermal coagulation front. The root mean square difference between ultrasonically and visually determined coagulation depths was 0.77 mm. This good agreement between visually inspected and ultrasonically determined coagulation depths shows the potential of our technique for monitoring coagulative tissue damage during thermal therapy.

AB - Thermal therapies using laser, microwaves, radio frequency radiation, and high intensity focused ultrasound have shown great promise for minimally invasive treatment of benign and malignant lesions. To treat tissue effectively and safely, techniques that could monitor the advancement of coagulation front during treatment are highly desirable. This paper presents a noninvasive ultrasound technique for automatically determining the propagation of coagulation damage front during laser tissue heating. The basic assumption underlying this technique is that when coagulation is taking place in a tissue, owing to thermally induced structure changes in tissue, the waveform of echo signal scattered from that treated region should be changing accordingly. We first track echoes scattered from many small tissue regions during heating using a cross-correlation echo-tracking technique. We then use the waveform-change information to determine the position of coagulation front via an automatic calculation procedure. To test our technique, we carried out 35 experiments in which we irradiated fresh canine liver samples with a Nd:YAG laser (1064-nm wavelength) at various light fluence (62 to 167 W/cm2) and exposure time (20 to 350 s). A 13-mm diameter 10-MHz broadband single-element spherical focused ultrasound transducer was used to detect the thermal coagulation front. The root mean square difference between ultrasonically and visually determined coagulation depths was 0.77 mm. This good agreement between visually inspected and ultrasonically determined coagulation depths shows the potential of our technique for monitoring coagulative tissue damage during thermal therapy.

UR - http://www.scopus.com/inward/record.url?scp=0033276772&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0033276772&partnerID=8YFLogxK

U2 - 10.1109/58.796119

DO - 10.1109/58.796119

M3 - Article

C2 - 18244307

AN - SCOPUS:0033276772

VL - 46

SP - 1134

EP - 1146

JO - IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control

JF - IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control

SN - 0885-3010

IS - 5

ER -