Biomechanical evaluation of a knotless barbed suture repair in a human Achilles tendon rupture model

Brian N. Kanz, Randal P. Morris, Taylor Lewis, Vinod Panchbhavi

Research output: Contribution to journalArticle

9 Citations (Scopus)

Abstract

BACKGROUND: Knotless barbed sutures are seeing more common use in wound closures and small tendon repairs. The purpose of this study was to evaluate the strength and resistance to gap formation of these sutures in larger tendons, such as the Achilles, compared with conventional repair.

METHODS: Six matched pairs of fresh-frozen human cadaver Achilles tendons were transected to simulate a rupture. Six tendons were repaired using a double Bunnell over-the-top technique with Fiberwire, and the matched pairs were repaired using a double Bunnell knotless technique with barbed suture. The tendons were tested to failure and stiffness, peak failure load, percentage elongation, load at initial gap and load at 5-mm gap (clinical failure) were compared.

RESULTS: The mean peak failure load for the Fiberwire group (459 N) was significantly higher (P = .029) compared with the barbed suture group (184 N). Percentage elongation at peak load was significantly lower in the barbed suture group (P = .014), as was percentage elongation at initial gapping (P = .007) and percent elongation at 5 mm of gapping (P = .004).

CONCLUSION: While the knotless barbed suture is attractive for its design and resistance to gap formation, low failure loads compared with conventional suture are concerning for large tendon repairs.

LEVELS OF EVIDENCE: Therapeutic, Level IV: Bench testing.

Original languageEnglish (US)
Pages (from-to)176-181
Number of pages6
JournalFoot & ankle specialist
Volume7
Issue number3
DOIs
StatePublished - Jun 1 2014

Fingerprint

Achilles Tendon
Sutures
Rupture
Tendons
Cadaver
Wounds and Injuries

Keywords

  • Achilles tendon
  • barbed suture
  • tendon repair

ASJC Scopus subject areas

  • Medicine(all)

Cite this

Biomechanical evaluation of a knotless barbed suture repair in a human Achilles tendon rupture model. / Kanz, Brian N.; Morris, Randal P.; Lewis, Taylor; Panchbhavi, Vinod.

In: Foot & ankle specialist, Vol. 7, No. 3, 01.06.2014, p. 176-181.

Research output: Contribution to journalArticle

Kanz, Brian N. ; Morris, Randal P. ; Lewis, Taylor ; Panchbhavi, Vinod. / Biomechanical evaluation of a knotless barbed suture repair in a human Achilles tendon rupture model. In: Foot & ankle specialist. 2014 ; Vol. 7, No. 3. pp. 176-181.
@article{7a575e6139c148a68237eb137d5a7567,
title = "Biomechanical evaluation of a knotless barbed suture repair in a human Achilles tendon rupture model",
abstract = "BACKGROUND: Knotless barbed sutures are seeing more common use in wound closures and small tendon repairs. The purpose of this study was to evaluate the strength and resistance to gap formation of these sutures in larger tendons, such as the Achilles, compared with conventional repair.METHODS: Six matched pairs of fresh-frozen human cadaver Achilles tendons were transected to simulate a rupture. Six tendons were repaired using a double Bunnell over-the-top technique with Fiberwire, and the matched pairs were repaired using a double Bunnell knotless technique with barbed suture. The tendons were tested to failure and stiffness, peak failure load, percentage elongation, load at initial gap and load at 5-mm gap (clinical failure) were compared.RESULTS: The mean peak failure load for the Fiberwire group (459 N) was significantly higher (P = .029) compared with the barbed suture group (184 N). Percentage elongation at peak load was significantly lower in the barbed suture group (P = .014), as was percentage elongation at initial gapping (P = .007) and percent elongation at 5 mm of gapping (P = .004).CONCLUSION: While the knotless barbed suture is attractive for its design and resistance to gap formation, low failure loads compared with conventional suture are concerning for large tendon repairs.LEVELS OF EVIDENCE: Therapeutic, Level IV: Bench testing.",
keywords = "Achilles tendon, barbed suture, tendon repair",
author = "Kanz, {Brian N.} and Morris, {Randal P.} and Taylor Lewis and Vinod Panchbhavi",
year = "2014",
month = "6",
day = "1",
doi = "10.1177/1938640014528041",
language = "English (US)",
volume = "7",
pages = "176--181",
journal = "Foot & ankle specialist",
issn = "1938-6400",
publisher = "SAGE Publications Ltd",
number = "3",

}

TY - JOUR

T1 - Biomechanical evaluation of a knotless barbed suture repair in a human Achilles tendon rupture model

AU - Kanz, Brian N.

AU - Morris, Randal P.

AU - Lewis, Taylor

AU - Panchbhavi, Vinod

PY - 2014/6/1

Y1 - 2014/6/1

N2 - BACKGROUND: Knotless barbed sutures are seeing more common use in wound closures and small tendon repairs. The purpose of this study was to evaluate the strength and resistance to gap formation of these sutures in larger tendons, such as the Achilles, compared with conventional repair.METHODS: Six matched pairs of fresh-frozen human cadaver Achilles tendons were transected to simulate a rupture. Six tendons were repaired using a double Bunnell over-the-top technique with Fiberwire, and the matched pairs were repaired using a double Bunnell knotless technique with barbed suture. The tendons were tested to failure and stiffness, peak failure load, percentage elongation, load at initial gap and load at 5-mm gap (clinical failure) were compared.RESULTS: The mean peak failure load for the Fiberwire group (459 N) was significantly higher (P = .029) compared with the barbed suture group (184 N). Percentage elongation at peak load was significantly lower in the barbed suture group (P = .014), as was percentage elongation at initial gapping (P = .007) and percent elongation at 5 mm of gapping (P = .004).CONCLUSION: While the knotless barbed suture is attractive for its design and resistance to gap formation, low failure loads compared with conventional suture are concerning for large tendon repairs.LEVELS OF EVIDENCE: Therapeutic, Level IV: Bench testing.

AB - BACKGROUND: Knotless barbed sutures are seeing more common use in wound closures and small tendon repairs. The purpose of this study was to evaluate the strength and resistance to gap formation of these sutures in larger tendons, such as the Achilles, compared with conventional repair.METHODS: Six matched pairs of fresh-frozen human cadaver Achilles tendons were transected to simulate a rupture. Six tendons were repaired using a double Bunnell over-the-top technique with Fiberwire, and the matched pairs were repaired using a double Bunnell knotless technique with barbed suture. The tendons were tested to failure and stiffness, peak failure load, percentage elongation, load at initial gap and load at 5-mm gap (clinical failure) were compared.RESULTS: The mean peak failure load for the Fiberwire group (459 N) was significantly higher (P = .029) compared with the barbed suture group (184 N). Percentage elongation at peak load was significantly lower in the barbed suture group (P = .014), as was percentage elongation at initial gapping (P = .007) and percent elongation at 5 mm of gapping (P = .004).CONCLUSION: While the knotless barbed suture is attractive for its design and resistance to gap formation, low failure loads compared with conventional suture are concerning for large tendon repairs.LEVELS OF EVIDENCE: Therapeutic, Level IV: Bench testing.

KW - Achilles tendon

KW - barbed suture

KW - tendon repair

UR - http://www.scopus.com/inward/record.url?scp=84922020336&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84922020336&partnerID=8YFLogxK

U2 - 10.1177/1938640014528041

DO - 10.1177/1938640014528041

M3 - Article

VL - 7

SP - 176

EP - 181

JO - Foot & ankle specialist

JF - Foot & ankle specialist

SN - 1938-6400

IS - 3

ER -