Chapter 2 Basic Laser Tweezers

Ronald E. Sterba, Michael Sheetz

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

This chapter discusses the basic laser tweezers. The basic information for designing and building a laser tweezers system for force measurements is provided in the chapter. If force measurements are not required, then the considerations about the analysis system, a fine piezo stage, and stability are less important. For the initial alignment and characterization of the system, red blood cells provide an easily trapped sample. For a difficult test sample, the smaller latex beads are stable and easy to obtain. Anyone setting up laser tweezers is encouraged to see a working tweezers system and to compare samples with that system. This basic system would include a low-power infrared (IR) laser, mirrors, and focusing lenses, which can be added to a good research microscope. The major limitations of the basic system are the laser power and stability needed for force measurements, and the proper laser beam configuration required for trapping small particles.

Original languageEnglish (US)
Pages (from-to)29-41
Number of pages13
JournalMethods in cell biology
Volume55
Issue numberC
DOIs
StatePublished - Jan 1 1997
Externally publishedYes

Fingerprint

Optical Tweezers
Lasers
Microspheres
Lenses
Erythrocytes
Research

ASJC Scopus subject areas

  • Cell Biology

Cite this

Chapter 2 Basic Laser Tweezers. / Sterba, Ronald E.; Sheetz, Michael.

In: Methods in cell biology, Vol. 55, No. C, 01.01.1997, p. 29-41.

Research output: Contribution to journalArticle

Sterba, Ronald E. ; Sheetz, Michael. / Chapter 2 Basic Laser Tweezers. In: Methods in cell biology. 1997 ; Vol. 55, No. C. pp. 29-41.
@article{3b208517e27448b7b1cb484b8cedd339,
title = "Chapter 2 Basic Laser Tweezers",
abstract = "This chapter discusses the basic laser tweezers. The basic information for designing and building a laser tweezers system for force measurements is provided in the chapter. If force measurements are not required, then the considerations about the analysis system, a fine piezo stage, and stability are less important. For the initial alignment and characterization of the system, red blood cells provide an easily trapped sample. For a difficult test sample, the smaller latex beads are stable and easy to obtain. Anyone setting up laser tweezers is encouraged to see a working tweezers system and to compare samples with that system. This basic system would include a low-power infrared (IR) laser, mirrors, and focusing lenses, which can be added to a good research microscope. The major limitations of the basic system are the laser power and stability needed for force measurements, and the proper laser beam configuration required for trapping small particles.",
author = "Sterba, {Ronald E.} and Michael Sheetz",
year = "1997",
month = "1",
day = "1",
doi = "10.1016/S0091-679X(08)60400-8",
language = "English (US)",
volume = "55",
pages = "29--41",
journal = "Methods in Cell Biology",
issn = "0091-679X",
publisher = "Academic Press Inc.",
number = "C",

}

TY - JOUR

T1 - Chapter 2 Basic Laser Tweezers

AU - Sterba, Ronald E.

AU - Sheetz, Michael

PY - 1997/1/1

Y1 - 1997/1/1

N2 - This chapter discusses the basic laser tweezers. The basic information for designing and building a laser tweezers system for force measurements is provided in the chapter. If force measurements are not required, then the considerations about the analysis system, a fine piezo stage, and stability are less important. For the initial alignment and characterization of the system, red blood cells provide an easily trapped sample. For a difficult test sample, the smaller latex beads are stable and easy to obtain. Anyone setting up laser tweezers is encouraged to see a working tweezers system and to compare samples with that system. This basic system would include a low-power infrared (IR) laser, mirrors, and focusing lenses, which can be added to a good research microscope. The major limitations of the basic system are the laser power and stability needed for force measurements, and the proper laser beam configuration required for trapping small particles.

AB - This chapter discusses the basic laser tweezers. The basic information for designing and building a laser tweezers system for force measurements is provided in the chapter. If force measurements are not required, then the considerations about the analysis system, a fine piezo stage, and stability are less important. For the initial alignment and characterization of the system, red blood cells provide an easily trapped sample. For a difficult test sample, the smaller latex beads are stable and easy to obtain. Anyone setting up laser tweezers is encouraged to see a working tweezers system and to compare samples with that system. This basic system would include a low-power infrared (IR) laser, mirrors, and focusing lenses, which can be added to a good research microscope. The major limitations of the basic system are the laser power and stability needed for force measurements, and the proper laser beam configuration required for trapping small particles.

UR - http://www.scopus.com/inward/record.url?scp=84857840985&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84857840985&partnerID=8YFLogxK

U2 - 10.1016/S0091-679X(08)60400-8

DO - 10.1016/S0091-679X(08)60400-8

M3 - Article

AN - SCOPUS:84857840985

VL - 55

SP - 29

EP - 41

JO - Methods in Cell Biology

JF - Methods in Cell Biology

SN - 0091-679X

IS - C

ER -