Characterization of abdominally acquired uterine electrical signals in humans, using a non-linear analytic method

William L. Maner, Lynette B. MacKay, George Saade, Robert E. Garfield

Research output: Contribution to journalArticle

29 Citations (Scopus)

Abstract

The present work seeks to determine if a particular non-linear analytic method is effective at quantifying uterine electromyography (EMG) data for estimating the onset of labor. Twenty-seven patients were included, and their uterine EMG was recorded non-invasively for 30 min. The patients were grouped into two sets: G1: labor, N=14; G2: antepartum, N=13. G1 patients all delivered spontaneously within 24 h of recording while G2 patients did not. The uterine electrical signals were analyzed offline by first isolating the uterine-specific frequency range and then randomly selecting "bursts" of uterine electrical activity (each associated with a uterine contraction) from every recording. Wavelet transform was subsequently applied to each of the bursts' traces, and then the fractal dimension (FD) of the resulting transformed EMG burst-trace was calculated (Benoit 1.3, Trusoft). Average burst FD was found for each patient. FD means for G1 and G2 were calculated and compared using t test. FD was significantly higher (P<0.05) for G1: 1.27±0.03 versus G2: 1.25±0.02. The wavelet-decomposition-generated fractal dimension can be used to successfully discern between patients who will deliver spontaneously within 24 h and those who will not, and can be useful for the objective classification of antepartum versus labor patients.

Original languageEnglish (US)
Pages (from-to)117-123
Number of pages7
JournalMedical and Biological Engineering and Computing
Volume44
Issue number1-2
DOIs
StatePublished - Mar 2006

Fingerprint

Fractal dimension
Fractals
Electromyography
Personnel
Wavelet decomposition
Labor Onset
Wavelet transforms
Wavelet Analysis
Uterine Contraction

Keywords

  • Delivery
  • Electromyography
  • Fractal
  • Labor
  • Prediction
  • Uterus
  • Wavelet

ASJC Scopus subject areas

  • Biomedical Engineering
  • Health Informatics
  • Health Information Management
  • Computer Science Applications
  • Computational Theory and Mathematics

Cite this

Characterization of abdominally acquired uterine electrical signals in humans, using a non-linear analytic method. / Maner, William L.; MacKay, Lynette B.; Saade, George; Garfield, Robert E.

In: Medical and Biological Engineering and Computing, Vol. 44, No. 1-2, 03.2006, p. 117-123.

Research output: Contribution to journalArticle

@article{532a9c6a6a6242bc857ad46b4fb31d74,
title = "Characterization of abdominally acquired uterine electrical signals in humans, using a non-linear analytic method",
abstract = "The present work seeks to determine if a particular non-linear analytic method is effective at quantifying uterine electromyography (EMG) data for estimating the onset of labor. Twenty-seven patients were included, and their uterine EMG was recorded non-invasively for 30 min. The patients were grouped into two sets: G1: labor, N=14; G2: antepartum, N=13. G1 patients all delivered spontaneously within 24 h of recording while G2 patients did not. The uterine electrical signals were analyzed offline by first isolating the uterine-specific frequency range and then randomly selecting {"}bursts{"} of uterine electrical activity (each associated with a uterine contraction) from every recording. Wavelet transform was subsequently applied to each of the bursts' traces, and then the fractal dimension (FD) of the resulting transformed EMG burst-trace was calculated (Benoit 1.3, Trusoft). Average burst FD was found for each patient. FD means for G1 and G2 were calculated and compared using t test. FD was significantly higher (P<0.05) for G1: 1.27±0.03 versus G2: 1.25±0.02. The wavelet-decomposition-generated fractal dimension can be used to successfully discern between patients who will deliver spontaneously within 24 h and those who will not, and can be useful for the objective classification of antepartum versus labor patients.",
keywords = "Delivery, Electromyography, Fractal, Labor, Prediction, Uterus, Wavelet",
author = "Maner, {William L.} and MacKay, {Lynette B.} and George Saade and Garfield, {Robert E.}",
year = "2006",
month = "3",
doi = "10.1007/s11517-005-0011-3",
language = "English (US)",
volume = "44",
pages = "117--123",
journal = "Medical and Biological Engineering and Computing",
issn = "0140-0118",
publisher = "Springer Verlag",
number = "1-2",

}

TY - JOUR

T1 - Characterization of abdominally acquired uterine electrical signals in humans, using a non-linear analytic method

AU - Maner, William L.

AU - MacKay, Lynette B.

AU - Saade, George

AU - Garfield, Robert E.

PY - 2006/3

Y1 - 2006/3

N2 - The present work seeks to determine if a particular non-linear analytic method is effective at quantifying uterine electromyography (EMG) data for estimating the onset of labor. Twenty-seven patients were included, and their uterine EMG was recorded non-invasively for 30 min. The patients were grouped into two sets: G1: labor, N=14; G2: antepartum, N=13. G1 patients all delivered spontaneously within 24 h of recording while G2 patients did not. The uterine electrical signals were analyzed offline by first isolating the uterine-specific frequency range and then randomly selecting "bursts" of uterine electrical activity (each associated with a uterine contraction) from every recording. Wavelet transform was subsequently applied to each of the bursts' traces, and then the fractal dimension (FD) of the resulting transformed EMG burst-trace was calculated (Benoit 1.3, Trusoft). Average burst FD was found for each patient. FD means for G1 and G2 were calculated and compared using t test. FD was significantly higher (P<0.05) for G1: 1.27±0.03 versus G2: 1.25±0.02. The wavelet-decomposition-generated fractal dimension can be used to successfully discern between patients who will deliver spontaneously within 24 h and those who will not, and can be useful for the objective classification of antepartum versus labor patients.

AB - The present work seeks to determine if a particular non-linear analytic method is effective at quantifying uterine electromyography (EMG) data for estimating the onset of labor. Twenty-seven patients were included, and their uterine EMG was recorded non-invasively for 30 min. The patients were grouped into two sets: G1: labor, N=14; G2: antepartum, N=13. G1 patients all delivered spontaneously within 24 h of recording while G2 patients did not. The uterine electrical signals were analyzed offline by first isolating the uterine-specific frequency range and then randomly selecting "bursts" of uterine electrical activity (each associated with a uterine contraction) from every recording. Wavelet transform was subsequently applied to each of the bursts' traces, and then the fractal dimension (FD) of the resulting transformed EMG burst-trace was calculated (Benoit 1.3, Trusoft). Average burst FD was found for each patient. FD means for G1 and G2 were calculated and compared using t test. FD was significantly higher (P<0.05) for G1: 1.27±0.03 versus G2: 1.25±0.02. The wavelet-decomposition-generated fractal dimension can be used to successfully discern between patients who will deliver spontaneously within 24 h and those who will not, and can be useful for the objective classification of antepartum versus labor patients.

KW - Delivery

KW - Electromyography

KW - Fractal

KW - Labor

KW - Prediction

KW - Uterus

KW - Wavelet

UR - http://www.scopus.com/inward/record.url?scp=33745479747&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33745479747&partnerID=8YFLogxK

U2 - 10.1007/s11517-005-0011-3

DO - 10.1007/s11517-005-0011-3

M3 - Article

VL - 44

SP - 117

EP - 123

JO - Medical and Biological Engineering and Computing

JF - Medical and Biological Engineering and Computing

SN - 0140-0118

IS - 1-2

ER -