TY - JOUR
T1 - Comparative safety, efficacy, and predictors of complete occlusion of flow diverter devices in the treatment of unruptured distal anterior cerebral artery aneurysms
AU - the CRETA Investigators
AU - Salim, Hamza Adel
AU - Scarcia, Luca
AU - Clarençon, Frédéric
AU - Hajjeh, Orabi
AU - Daraghma, Motaz
AU - Simonato, Davide
AU - Li, Yan Lin
AU - Shotar, Eimad
AU - Premat, Kevin
AU - Jabbour, Pascal
AU - Tjoumakaris, Stavropoula I.
AU - Gooch, Reid M.
AU - Psychogios, Marios
AU - Ntoulias, Nikos
AU - Sporns, Peter
AU - Puri, Ajit S.
AU - Singh, Jasmeet
AU - Kuhn, Anna Luisa
AU - Hassan, Ameer E.
AU - Algin, Oktay
AU - Möhlenbruch, Markus A.
AU - Hohenstatt, Sophia
AU - Russo, Riccardo
AU - Bergui, Mauro
AU - Goren, Oded
AU - Kole, Matthew J.
AU - Bankole, Nourou Dine Adeniran
AU - Bibi, Richard
AU - Boulouis, Gregoire
AU - Morimoto, Takeshi
AU - Sakakibara, Fumihiro
AU - Pop, Raoul
AU - Juravle, Ciprian
AU - Ho, Joanna W.K.
AU - Ferrario, Ãngel
AU - Lereis, Virginia Pujol
AU - Cooper, Jared
AU - Gandhi, Chirag D.
AU - Salsano, Giancarlo
AU - Castellan, Lucio
AU - Consoli, Arturo
AU - Sgreccia, Alessandro
AU - Raz, Eytan
AU - Chung, Charlotte
AU - Burel, Julien
AU - Papagiannaki, Chrysanthi
AU - Rasheed, Umair
AU - Hassan, Khawaja Muhammad Baqir
AU - Tao, Hong
AU - Wintermark, Max
N1 - Publisher Copyright:
© The Author(s) 2026.
PY - 2026/3
Y1 - 2026/3
N2 - Background: Flow diverters (FDs) are increasingly used for cerebral aneurysms, including distal anterior cerebral artery (DACA) aneurysms, but comparative data between devices in this challenging location are limited. Objective: To compare the safety and efficacy of Pipeline, Silk Vista Baby (SVB), and FRED Jr. FDs for unruptured DACA aneurysms and identify predictors of complete occlusion. Methods: We retrospectively analyzed 166 patients treated with FDs at 39 centers in 14 countries (2018–2022) from the CRETA registry. Outcomes included aneurysm occlusion (O’Kelly–Marotta [OKM] scale), complications, retreatment, modified Rankin Scale (mRS) scores, and independent predictors of complete occlusion using multivariable Cox regression. Results: Aneurysms were predominantly saccular and located on the pericallosal artery. Complete occlusion (OKM D) was achieved in 73%, and neck remnants (OKM C) in 12%, with no differences across devices. Ischemic complications occurred in 11% (mostly asymptomatic), hemorrhagic complications in 5%, and in-stent stenosis in 17%. Retreatment was performed in 1.3%. At last follow-up, 98% had mRS ≤ 2. Independent predictors of complete occlusion were female sex (HR 1.85), asymptomatic presentation (HR 1.79), smaller aneurysm neck (HR 0.83/mm), radial access (HR 2.20), and aspirin plus ticagrelor therapy (HR 1.84); device type was not predictive. Conclusion: Pipeline, SVB, and FRED Jr. FDs show similar safety and efficacy for unruptured DACA aneurysms. Complete occlusion is influenced by clinical and procedural factors, supporting individualized device selection.
AB - Background: Flow diverters (FDs) are increasingly used for cerebral aneurysms, including distal anterior cerebral artery (DACA) aneurysms, but comparative data between devices in this challenging location are limited. Objective: To compare the safety and efficacy of Pipeline, Silk Vista Baby (SVB), and FRED Jr. FDs for unruptured DACA aneurysms and identify predictors of complete occlusion. Methods: We retrospectively analyzed 166 patients treated with FDs at 39 centers in 14 countries (2018–2022) from the CRETA registry. Outcomes included aneurysm occlusion (O’Kelly–Marotta [OKM] scale), complications, retreatment, modified Rankin Scale (mRS) scores, and independent predictors of complete occlusion using multivariable Cox regression. Results: Aneurysms were predominantly saccular and located on the pericallosal artery. Complete occlusion (OKM D) was achieved in 73%, and neck remnants (OKM C) in 12%, with no differences across devices. Ischemic complications occurred in 11% (mostly asymptomatic), hemorrhagic complications in 5%, and in-stent stenosis in 17%. Retreatment was performed in 1.3%. At last follow-up, 98% had mRS ≤ 2. Independent predictors of complete occlusion were female sex (HR 1.85), asymptomatic presentation (HR 1.79), smaller aneurysm neck (HR 0.83/mm), radial access (HR 2.20), and aspirin plus ticagrelor therapy (HR 1.84); device type was not predictive. Conclusion: Pipeline, SVB, and FRED Jr. FDs show similar safety and efficacy for unruptured DACA aneurysms. Complete occlusion is influenced by clinical and procedural factors, supporting individualized device selection.
KW - Aneurysm occlusion
KW - Distal anterior cerebral artery aneurysms
KW - Endovascular treatment
KW - Flow diverter devices
UR - https://www.scopus.com/pages/publications/105030534650
UR - https://www.scopus.com/pages/publications/105030534650#tab=citedBy
U2 - 10.1007/s10072-026-08869-w
DO - 10.1007/s10072-026-08869-w
M3 - Article
C2 - 41706217
AN - SCOPUS:105030534650
SN - 1590-1874
VL - 47
JO - Neurological Sciences
JF - Neurological Sciences
IS - 3
M1 - 270
ER -