TY - GEN
T1 - Coordinate system considerations in the creation of a 3-D dynamic model
AU - Grierson, Y. M.
AU - Riley, P. O.
AU - Benda, B. J.
AU - Tucker, C. A.
N1 - Funding Information:
This work was supported in part by The Whitaker Foundation, and by Grants H133P90005 and H133G00025 from the National Institute of Disability and Rehabilitation Research This paper will descnbe the coordinate system transformations necessary to reformat published anthropometric data for inclusion in a predefined 3-D body model. A 3-D dynamic model requires input from several sources that often have different frames of reference. Through a series of coordinate transformations and data manipulations the various frames of reference can be brought into coincidence. This allows for the creation of one coherent model as the one which has been developed at the MGH Biomotion Laboratory.
Publisher Copyright:
© 1992 IEEE.
PY - 1992
Y1 - 1992
N2 - The authors describe the coordinate system transformations necessary to reformat published anthropometric data for inclusion in a predefined 3-D body model. A 3-D dynamic model requires input from several sources that often have different frames of reference. Through a series of coordinate transformations and data manipulations, the various frames of reference can be brought into coincidence. This allows for the creation of one coherent model. One such model, developed at the Massachusetts General Hospital, is described.
AB - The authors describe the coordinate system transformations necessary to reformat published anthropometric data for inclusion in a predefined 3-D body model. A 3-D dynamic model requires input from several sources that often have different frames of reference. Through a series of coordinate transformations and data manipulations, the various frames of reference can be brought into coincidence. This allows for the creation of one coherent model. One such model, developed at the Massachusetts General Hospital, is described.
UR - http://www.scopus.com/inward/record.url?scp=0345142807&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0345142807&partnerID=8YFLogxK
U2 - 10.1109/NEBC.1992.285991
DO - 10.1109/NEBC.1992.285991
M3 - Conference contribution
AN - SCOPUS:0345142807
T3 - Proceedings of the IEEE Annual Northeast Bioengineering Conference, NEBEC
SP - 147
EP - 148
BT - Proceedings of the 18th IEEE Annual Northeast Bioengineering Conference, NEBEC 1992
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 18th IEEE Annual Northeast Bioengineering Conference, NEBEC 1992
Y2 - 12 March 1992 through 13 March 1992