TY - JOUR
T1 - Corneal Scheimpflug Densitometry in Photorefractive Keratectomy Candidates
AU - Pakbin, Mojgan
AU - Khabazkhoob, Mehdi
AU - Pakravan, Mohammad
AU - Fotouhi, Akbar
AU - Jafarzadehpur, Ebrahim
AU - Aghamirsalim, Mohamadreza
AU - Hashemi, Hassan
N1 - Publisher Copyright:
© 2020 Lippincott Williams and Wilkins. All rights reserved.
PY - 2020/11/1
Y1 - 2020/11/1
N2 - Purpose:To describe the normative data of corneal densitometry in photorefractive Keratectomy (PRK) candidates by using a Scheimpflug camera.Methods:Five hundred twenty-two eyes of 261 PRK candidates that underwent comprehensive optometric and ophthalmic examinations were enrolled in this study. Corneal densitometry values were obtained using a Scheimpflug camera (Pentacam HR; Oculus Optikgeräte GmbH, Wetzlar, Germany) and displayed in grayscale units (GSU).Results:Of 261 participants, 187 (71.6%) were women. The mean age of the participants was 28.79 ± 5.02 years (range: 21-40 years). The mean entire corneal densitometry was 14.86 ± 2.37 GSU. According to corneal depth, maximum and minimum densitometry values were seen in the anterior (30.28 ± 7.42 GSU) and posterior (9.86 ± 2.08 GSU) layers, respectively (P < 0.001). Based on the annulus over the cornea, the highest and lowest densitometry values were seen in the 10- to 12-mm (21.31 ± 4.26 GSU) and 2- to 6-mm zones (13.26 ± 2.34 GSU), respectively. However, this difference was not seen after 35 years of age. Individuals aged 30 to 35 years showed higher corneal densitometry values compared with subjects aged 20 to 25 years old (P < 0.001). In generalized linear models, the corneal thickness was associated with the densitometry value in the central and posterior corneal layers. There were no significant differences in sex and refractive errors among participants.Conclusions:This study provided normal corneal densitometry data in PRK candidates. Corneal densitometry increased with age until 35 years of age and then decreased thereafter. This finding should be considered in patient selection for PRK and their postoperative examinations.
AB - Purpose:To describe the normative data of corneal densitometry in photorefractive Keratectomy (PRK) candidates by using a Scheimpflug camera.Methods:Five hundred twenty-two eyes of 261 PRK candidates that underwent comprehensive optometric and ophthalmic examinations were enrolled in this study. Corneal densitometry values were obtained using a Scheimpflug camera (Pentacam HR; Oculus Optikgeräte GmbH, Wetzlar, Germany) and displayed in grayscale units (GSU).Results:Of 261 participants, 187 (71.6%) were women. The mean age of the participants was 28.79 ± 5.02 years (range: 21-40 years). The mean entire corneal densitometry was 14.86 ± 2.37 GSU. According to corneal depth, maximum and minimum densitometry values were seen in the anterior (30.28 ± 7.42 GSU) and posterior (9.86 ± 2.08 GSU) layers, respectively (P < 0.001). Based on the annulus over the cornea, the highest and lowest densitometry values were seen in the 10- to 12-mm (21.31 ± 4.26 GSU) and 2- to 6-mm zones (13.26 ± 2.34 GSU), respectively. However, this difference was not seen after 35 years of age. Individuals aged 30 to 35 years showed higher corneal densitometry values compared with subjects aged 20 to 25 years old (P < 0.001). In generalized linear models, the corneal thickness was associated with the densitometry value in the central and posterior corneal layers. There were no significant differences in sex and refractive errors among participants.Conclusions:This study provided normal corneal densitometry data in PRK candidates. Corneal densitometry increased with age until 35 years of age and then decreased thereafter. This finding should be considered in patient selection for PRK and their postoperative examinations.
KW - Pentacam
KW - Scheimpflug camera
KW - corneal densitometry
KW - photorefractive keratometry
UR - http://www.scopus.com/inward/record.url?scp=85092663388&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85092663388&partnerID=8YFLogxK
U2 - 10.1097/ICO.0000000000002468
DO - 10.1097/ICO.0000000000002468
M3 - Article
C2 - 33017121
AN - SCOPUS:85092663388
SN - 0277-3740
VL - 39
SP - 1381
EP - 1388
JO - Cornea
JF - Cornea
IS - 11
ER -