Skip to main navigation Skip to search Skip to main content

Dynamic perfusion CT: Optimizing the temporal resolution and contrast volume for calculation of perfusion CT parameters in stroke patients

  • Max Wintermark
  • , Wade S. Smith
  • , Nerissa U. Ko
  • , Marcel Quist
  • , Pierre Schnyder
  • , William P. Dillon

Research output: Contribution to journalArticlepeer-review

Abstract

BACKGROUND AND PURPOSE: Numerous parameters are involved in dynamic perfusion CT (PCT). We assessed the influence of the temporal sampling rate and the volume of contrast material. METHODS: Sixty patients with ischemic hemispheric stroke lasting ≥12 hours underwent PCT. Groups of 15 patients each received 30, 40, 50, or 60 mL of contrast agent. Regional cerebral blood volume (rCBV), regional cerebral blood flow (rCBF), mean transit time (MTT), and time-to-peak (TTP) maps were calculated for temporal sampling intervals of 0.5, 1, 2, 3, 4, 5, and 6 seconds. Results were statistically compared. Signal-to-noise ratios (SNRs), duration of arterial entrance to venous exit, and radiation dose were also assessed. RESULTS: Increasing temporal sampling intervals lead to significant overestimation of rCBV, rCBF, and TTP and significant underestimation of MTT compared with values for an interval of 1 second. Maximal allowable intervals to avoid these effects were 2, 3, 3, and 4 seconds for 30, 40, 50, and 60-mL boluses, respectively. Venous exit of contrast material occurred in 97.5% of patients after 36, 42, 42, and 48 seconds, respectively, for the four volumes. SNRs did not differ with volume. The effective radiation dose varied between 0.852 and 1.867 mSv, depending on the protocol. The clue mode with two 40-mL boluses and the toggling-table technique with one 60-mL bolus had the lowest doses. CONCLUSION: Temporal sampling intervals greater than 1 second can be used without altering the quantitative accuracy of PCT. Increased sampling intervals reduce the radiation dose and may allow for increased spatial coverage.

Original languageEnglish (US)
Pages (from-to)720-729
Number of pages10
JournalAmerican Journal of Neuroradiology
Volume25
Issue number5
StatePublished - May 2004
Externally publishedYes

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Clinical Neurology

Fingerprint

Dive into the research topics of 'Dynamic perfusion CT: Optimizing the temporal resolution and contrast volume for calculation of perfusion CT parameters in stroke patients'. Together they form a unique fingerprint.

Cite this