Early postmarket results with embotrap II stent retriever for mechanical thrombectomy: a multicenter experience

  • A. Srivatsan
  • , V. M. Srinivasan
  • , R. M. Starke
  • , E. C. Peterson
  • , D. R. Yavagal
  • , A. E. Hassan
  • , A. Alawieh
  • , A. M. Spiotta
  • , Y. Saleem
  • , K. M. Fargen
  • , S. Q. Wolfe
  • , R. A. de Leacy
  • , I. P. Singh
  • , I. L. Maier
  • , J. N. Johnson
  • , J. K. Burkhardt
  • , S. R. Chen
  • , P. Kan

Research output: Contribution to journalArticlepeer-review

12 Scopus citations

Abstract

BACKGROUND AND PURPOSE: EmboTrap II is a novel stent retriever with a dual-layer design and distal mesh designed for acute ischemic stroke emergent large-vessel occlusions. We present the first postmarket prospective multicenter experience with the EmboTrap II stent retriever. MATERIALS AND METHODS: A prospective registry of patients treated with EmboTrap II at 7 centers following FDA approval was maintained with baseline patient characteristics, treatment details, and clinical/radiographic follow-up. RESULTS: Seventy patients were treated with EmboTrap II (mean age, 69.9 years; 48.6% women). Intravenous thrombolysis was given in 34.3%, and emergent large-vessel occlusions were located in the ICA (n ¼ 18), M1 (n ¼ 38), M2 or M3 (n ¼ 13), and basilar artery (n ¼ 1). The 5 33 mm device was used in 88% of cases. TICI $ 2b recanalization was achieved in 95.7% (82.3% in EmboTrap II–only cases), and first-pass efficacy was achieved in 35.7%. The NIHSS score improved from a preoperative average of 16.3 to 12.1 postprocedure and to 10.5 at discharge. An average of 2.5 [SD, 1.8] passes was recorded per treatment, including non-EmboTrap attempts. Definitive treatment was performed with an alternative device (aspiration or stent retriever) in 9 cases (12.9%). Some hemorrhagic conversion was noted in 22.9% of cases, of which 4.3% were symptomatic. There were no device-related complications. CONCLUSIONS: Initial postmarket results with the EmboTrap II stent retriever are favorable and comparable with those of other commercially available stent retrievers. Compared with EmboTrap II, the first-generation EmboTrap may have a higher first-pass efficacy; however, data are limited by retrospective case analysis, incomplete clinical follow-up, and small sample size, necessitating future trials.

Original languageEnglish (US)
Pages (from-to)904-909
Number of pages6
JournalAmerican Journal of Neuroradiology
Volume42
Issue number5
DOIs
StatePublished - May 1 2021