Effect of motion artifacts and scan circle displacements on cirrus HD-OCT retinal nerve fiber layer thickness measurements

Giovanni Taibbi, Gregory C. Peterson, Misha Syed, Gianmarco Vizzeri

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

Purpose. To evaluate the effect of scan circle displacements on retinal nerve fiber layer thickness (RNFLT) measurements in Cirrus HD-OCT scans with motion artifacts affecting the optic disc. Methods. In this cross-sectional study, 70 scans from 18 healthy eyes and 100 scans from 26 glaucomatous eyes were divided into 85 pairs, each composed by a scan with one motion artifact affecting the optic disc, and a scan from the same eye without motion artifacts. En face images underwent automated realignment, and horizontal/vertical scan circle displacements were determined. Multiple regression analysis evaluated the relationship between scan circle displacements and RNFLT change. Results. Scans with motion artifacts showed similar displacements in healthy and glaucomatous eyes (P values ≥ 0.08). Average RNFLT and quadrants were relatively unchanged, while clock-hours showed more changes (e.g., in glaucomatous eyes, clock-hour- 7 RNFLT was lower in scans with motion artifacts, P = 0.05). Scan circle displacements produced average RNFLT changes above test-retest variability in 3/85 cases (3.53%). Retinal nerve fiber layer thickness tended to decrease in sectors moved away from the disc and to increase in sectors closer to the disc (R2 ≤ 0.40 and R2 ≤ 0.22 in healthy and glaucomatous eyes, respectively). In healthy eyes, horizontal displacements ≥ 423 and 325 lm were associated with average and quadrant RNFLT changes above test-retest variability, respectively. Conclusions. Scan circle displacements occurred in all scans with motions artifacts affecting the optic disc. Average RNFLT and quadrants were more robust than clock-hours. Because motion artifacts may be difficult to detect, clinicians should carefully inspect en face OCT images for their presence and interpret clock-hour results cautiously.

Original languageEnglish (US)
Pages (from-to)2251-2258
Number of pages8
JournalInvestigative Ophthalmology and Visual Science
Volume55
Issue number4
DOIs
StatePublished - Apr 7 2014

Fingerprint

Nerve Fibers
Artifacts
Optic Disk
Cross-Sectional Studies
Regression Analysis

Keywords

  • Motion artifacts
  • Optic disc
  • Retinal nerve fiber layer thickness
  • Scan circle displacement
  • Spectral-domain OCT

ASJC Scopus subject areas

  • Ophthalmology
  • Sensory Systems
  • Cellular and Molecular Neuroscience

Cite this

Effect of motion artifacts and scan circle displacements on cirrus HD-OCT retinal nerve fiber layer thickness measurements. / Taibbi, Giovanni; Peterson, Gregory C.; Syed, Misha; Vizzeri, Gianmarco.

In: Investigative Ophthalmology and Visual Science, Vol. 55, No. 4, 07.04.2014, p. 2251-2258.

Research output: Contribution to journalArticle

@article{9dee51a476d84e669e2b03b7f1528319,
title = "Effect of motion artifacts and scan circle displacements on cirrus HD-OCT retinal nerve fiber layer thickness measurements",
abstract = "Purpose. To evaluate the effect of scan circle displacements on retinal nerve fiber layer thickness (RNFLT) measurements in Cirrus HD-OCT scans with motion artifacts affecting the optic disc. Methods. In this cross-sectional study, 70 scans from 18 healthy eyes and 100 scans from 26 glaucomatous eyes were divided into 85 pairs, each composed by a scan with one motion artifact affecting the optic disc, and a scan from the same eye without motion artifacts. En face images underwent automated realignment, and horizontal/vertical scan circle displacements were determined. Multiple regression analysis evaluated the relationship between scan circle displacements and RNFLT change. Results. Scans with motion artifacts showed similar displacements in healthy and glaucomatous eyes (P values ≥ 0.08). Average RNFLT and quadrants were relatively unchanged, while clock-hours showed more changes (e.g., in glaucomatous eyes, clock-hour- 7 RNFLT was lower in scans with motion artifacts, P = 0.05). Scan circle displacements produced average RNFLT changes above test-retest variability in 3/85 cases (3.53{\%}). Retinal nerve fiber layer thickness tended to decrease in sectors moved away from the disc and to increase in sectors closer to the disc (R2 ≤ 0.40 and R2 ≤ 0.22 in healthy and glaucomatous eyes, respectively). In healthy eyes, horizontal displacements ≥ 423 and 325 lm were associated with average and quadrant RNFLT changes above test-retest variability, respectively. Conclusions. Scan circle displacements occurred in all scans with motions artifacts affecting the optic disc. Average RNFLT and quadrants were more robust than clock-hours. Because motion artifacts may be difficult to detect, clinicians should carefully inspect en face OCT images for their presence and interpret clock-hour results cautiously.",
keywords = "Motion artifacts, Optic disc, Retinal nerve fiber layer thickness, Scan circle displacement, Spectral-domain OCT",
author = "Giovanni Taibbi and Peterson, {Gregory C.} and Misha Syed and Gianmarco Vizzeri",
year = "2014",
month = "4",
day = "7",
doi = "10.1167/iovs.13-13276",
language = "English (US)",
volume = "55",
pages = "2251--2258",
journal = "Investigative Ophthalmology and Visual Science",
issn = "0146-0404",
publisher = "Association for Research in Vision and Ophthalmology Inc.",
number = "4",

}

TY - JOUR

T1 - Effect of motion artifacts and scan circle displacements on cirrus HD-OCT retinal nerve fiber layer thickness measurements

AU - Taibbi, Giovanni

AU - Peterson, Gregory C.

AU - Syed, Misha

AU - Vizzeri, Gianmarco

PY - 2014/4/7

Y1 - 2014/4/7

N2 - Purpose. To evaluate the effect of scan circle displacements on retinal nerve fiber layer thickness (RNFLT) measurements in Cirrus HD-OCT scans with motion artifacts affecting the optic disc. Methods. In this cross-sectional study, 70 scans from 18 healthy eyes and 100 scans from 26 glaucomatous eyes were divided into 85 pairs, each composed by a scan with one motion artifact affecting the optic disc, and a scan from the same eye without motion artifacts. En face images underwent automated realignment, and horizontal/vertical scan circle displacements were determined. Multiple regression analysis evaluated the relationship between scan circle displacements and RNFLT change. Results. Scans with motion artifacts showed similar displacements in healthy and glaucomatous eyes (P values ≥ 0.08). Average RNFLT and quadrants were relatively unchanged, while clock-hours showed more changes (e.g., in glaucomatous eyes, clock-hour- 7 RNFLT was lower in scans with motion artifacts, P = 0.05). Scan circle displacements produced average RNFLT changes above test-retest variability in 3/85 cases (3.53%). Retinal nerve fiber layer thickness tended to decrease in sectors moved away from the disc and to increase in sectors closer to the disc (R2 ≤ 0.40 and R2 ≤ 0.22 in healthy and glaucomatous eyes, respectively). In healthy eyes, horizontal displacements ≥ 423 and 325 lm were associated with average and quadrant RNFLT changes above test-retest variability, respectively. Conclusions. Scan circle displacements occurred in all scans with motions artifacts affecting the optic disc. Average RNFLT and quadrants were more robust than clock-hours. Because motion artifacts may be difficult to detect, clinicians should carefully inspect en face OCT images for their presence and interpret clock-hour results cautiously.

AB - Purpose. To evaluate the effect of scan circle displacements on retinal nerve fiber layer thickness (RNFLT) measurements in Cirrus HD-OCT scans with motion artifacts affecting the optic disc. Methods. In this cross-sectional study, 70 scans from 18 healthy eyes and 100 scans from 26 glaucomatous eyes were divided into 85 pairs, each composed by a scan with one motion artifact affecting the optic disc, and a scan from the same eye without motion artifacts. En face images underwent automated realignment, and horizontal/vertical scan circle displacements were determined. Multiple regression analysis evaluated the relationship between scan circle displacements and RNFLT change. Results. Scans with motion artifacts showed similar displacements in healthy and glaucomatous eyes (P values ≥ 0.08). Average RNFLT and quadrants were relatively unchanged, while clock-hours showed more changes (e.g., in glaucomatous eyes, clock-hour- 7 RNFLT was lower in scans with motion artifacts, P = 0.05). Scan circle displacements produced average RNFLT changes above test-retest variability in 3/85 cases (3.53%). Retinal nerve fiber layer thickness tended to decrease in sectors moved away from the disc and to increase in sectors closer to the disc (R2 ≤ 0.40 and R2 ≤ 0.22 in healthy and glaucomatous eyes, respectively). In healthy eyes, horizontal displacements ≥ 423 and 325 lm were associated with average and quadrant RNFLT changes above test-retest variability, respectively. Conclusions. Scan circle displacements occurred in all scans with motions artifacts affecting the optic disc. Average RNFLT and quadrants were more robust than clock-hours. Because motion artifacts may be difficult to detect, clinicians should carefully inspect en face OCT images for their presence and interpret clock-hour results cautiously.

KW - Motion artifacts

KW - Optic disc

KW - Retinal nerve fiber layer thickness

KW - Scan circle displacement

KW - Spectral-domain OCT

UR - http://www.scopus.com/inward/record.url?scp=84898750041&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84898750041&partnerID=8YFLogxK

U2 - 10.1167/iovs.13-13276

DO - 10.1167/iovs.13-13276

M3 - Article

VL - 55

SP - 2251

EP - 2258

JO - Investigative Ophthalmology and Visual Science

JF - Investigative Ophthalmology and Visual Science

SN - 0146-0404

IS - 4

ER -