Evaluating Which Dose-Function Metrics Are Most Critical for Functional-Guided Radiation Therapy

Austin M. Faught, Tokihiro Yamamoto, Richard Castillo, Edward Castillo, Jingjing Zhang, Moyed Miften, Yevgeniy Vinogradskiy

Research output: Contribution to journalArticle

14 Citations (Scopus)

Abstract

Purpose Four-dimensional (4D) computed tomography (CT) ventilation imaging is increasingly being used to calculate lung ventilation and implement functional-guided radiation therapy in clinical trials. There has been little exhaustive work evaluating which dose-function metrics should be used for treatment planning and plan evaluation. The purpose of our study was to evaluate which dose-function metrics best predict for radiation pneumonitis (RP). Methods and Materials Seventy lung cancer patients who underwent 4D CT imaging and pneumonitis grading were assessed. Pretreatment 4D CT scans of each patient were used to calculate ventilation images. We evaluated 3 types of dose-function metrics that combined the patient's 4D CT ventilation image and treatment planning dose distribution: (1) structure-based approaches; (2) image-based approaches using the dose-function histogram; and (3) nonlinear weighting schemes. Log-likelihood methods were used to generate normal tissue complication probability models predicting grade 3 or higher (ie, grade 3+) pneumonitis for all dose-function schemes. The area under the curve (AUC) was used to assess the predictive power of the models. All techniques were compared with normal tissue complication probability models based on traditional, total lung dose metrics. Results The most predictive models were structure-based approaches that focused on the volume of functional lung receiving ≥20 Gy (AUC, 0.70). Probabilities of grade 3+ RP of 20% and 10% correspond to V20 (percentage of volume receiving ≥20 Gy) to the functional subvolumes of 26.8% and 9.3%, respectively. Imaging-based analysis with the dose-function histogram and nonlinear weighted ventilation values yielded AUCs of 0.66 and 0.67, respectively, when we evaluated the percentage of functionality receiving ≥20 Gy. All dose-function metrics outperformed the traditional dose metrics (mean lung dose, AUC of 0.55). Conclusions A full range of dose-function metrics and functional thresholds was examined. The calculated AUC values for the most predictive functional models occupied a narrow range (0.66-0.70), and all showed notable improvements over AUC from traditional lung dose metrics (0.55). Identifying the combinations most predictive of grade 3+ RP provides valuable data to inform the functional-guided radiation therapy process.

Original languageEnglish (US)
Pages (from-to)202-209
Number of pages8
JournalInternational Journal of Radiation Oncology Biology Physics
Volume99
Issue number1
DOIs
StatePublished - Sep 1 2017
Externally publishedYes

Fingerprint

Four-Dimensional Computed Tomography
Area Under Curve
radiation therapy
Radiotherapy
Radiation Pneumonitis
dosage
Lung
Ventilation
ventilation
lungs
Pneumonia
grade
tomography
curves
histograms
Lung Neoplasms
planning
radiation
Clinical Trials
Therapeutics

ASJC Scopus subject areas

  • Radiation
  • Oncology
  • Radiology Nuclear Medicine and imaging
  • Cancer Research

Cite this

Evaluating Which Dose-Function Metrics Are Most Critical for Functional-Guided Radiation Therapy. / Faught, Austin M.; Yamamoto, Tokihiro; Castillo, Richard; Castillo, Edward; Zhang, Jingjing; Miften, Moyed; Vinogradskiy, Yevgeniy.

In: International Journal of Radiation Oncology Biology Physics, Vol. 99, No. 1, 01.09.2017, p. 202-209.

Research output: Contribution to journalArticle

Faught, Austin M. ; Yamamoto, Tokihiro ; Castillo, Richard ; Castillo, Edward ; Zhang, Jingjing ; Miften, Moyed ; Vinogradskiy, Yevgeniy. / Evaluating Which Dose-Function Metrics Are Most Critical for Functional-Guided Radiation Therapy. In: International Journal of Radiation Oncology Biology Physics. 2017 ; Vol. 99, No. 1. pp. 202-209.
@article{f0778789a74546e4bec959a737f1078a,
title = "Evaluating Which Dose-Function Metrics Are Most Critical for Functional-Guided Radiation Therapy",
abstract = "Purpose Four-dimensional (4D) computed tomography (CT) ventilation imaging is increasingly being used to calculate lung ventilation and implement functional-guided radiation therapy in clinical trials. There has been little exhaustive work evaluating which dose-function metrics should be used for treatment planning and plan evaluation. The purpose of our study was to evaluate which dose-function metrics best predict for radiation pneumonitis (RP). Methods and Materials Seventy lung cancer patients who underwent 4D CT imaging and pneumonitis grading were assessed. Pretreatment 4D CT scans of each patient were used to calculate ventilation images. We evaluated 3 types of dose-function metrics that combined the patient's 4D CT ventilation image and treatment planning dose distribution: (1) structure-based approaches; (2) image-based approaches using the dose-function histogram; and (3) nonlinear weighting schemes. Log-likelihood methods were used to generate normal tissue complication probability models predicting grade 3 or higher (ie, grade 3+) pneumonitis for all dose-function schemes. The area under the curve (AUC) was used to assess the predictive power of the models. All techniques were compared with normal tissue complication probability models based on traditional, total lung dose metrics. Results The most predictive models were structure-based approaches that focused on the volume of functional lung receiving ≥20 Gy (AUC, 0.70). Probabilities of grade 3+ RP of 20{\%} and 10{\%} correspond to V20 (percentage of volume receiving ≥20 Gy) to the functional subvolumes of 26.8{\%} and 9.3{\%}, respectively. Imaging-based analysis with the dose-function histogram and nonlinear weighted ventilation values yielded AUCs of 0.66 and 0.67, respectively, when we evaluated the percentage of functionality receiving ≥20 Gy. All dose-function metrics outperformed the traditional dose metrics (mean lung dose, AUC of 0.55). Conclusions A full range of dose-function metrics and functional thresholds was examined. The calculated AUC values for the most predictive functional models occupied a narrow range (0.66-0.70), and all showed notable improvements over AUC from traditional lung dose metrics (0.55). Identifying the combinations most predictive of grade 3+ RP provides valuable data to inform the functional-guided radiation therapy process.",
author = "Faught, {Austin M.} and Tokihiro Yamamoto and Richard Castillo and Edward Castillo and Jingjing Zhang and Moyed Miften and Yevgeniy Vinogradskiy",
year = "2017",
month = "9",
day = "1",
doi = "10.1016/j.ijrobp.2017.03.051",
language = "English (US)",
volume = "99",
pages = "202--209",
journal = "International Journal of Radiation Oncology Biology Physics",
issn = "0360-3016",
publisher = "Elsevier Inc.",
number = "1",

}

TY - JOUR

T1 - Evaluating Which Dose-Function Metrics Are Most Critical for Functional-Guided Radiation Therapy

AU - Faught, Austin M.

AU - Yamamoto, Tokihiro

AU - Castillo, Richard

AU - Castillo, Edward

AU - Zhang, Jingjing

AU - Miften, Moyed

AU - Vinogradskiy, Yevgeniy

PY - 2017/9/1

Y1 - 2017/9/1

N2 - Purpose Four-dimensional (4D) computed tomography (CT) ventilation imaging is increasingly being used to calculate lung ventilation and implement functional-guided radiation therapy in clinical trials. There has been little exhaustive work evaluating which dose-function metrics should be used for treatment planning and plan evaluation. The purpose of our study was to evaluate which dose-function metrics best predict for radiation pneumonitis (RP). Methods and Materials Seventy lung cancer patients who underwent 4D CT imaging and pneumonitis grading were assessed. Pretreatment 4D CT scans of each patient were used to calculate ventilation images. We evaluated 3 types of dose-function metrics that combined the patient's 4D CT ventilation image and treatment planning dose distribution: (1) structure-based approaches; (2) image-based approaches using the dose-function histogram; and (3) nonlinear weighting schemes. Log-likelihood methods were used to generate normal tissue complication probability models predicting grade 3 or higher (ie, grade 3+) pneumonitis for all dose-function schemes. The area under the curve (AUC) was used to assess the predictive power of the models. All techniques were compared with normal tissue complication probability models based on traditional, total lung dose metrics. Results The most predictive models were structure-based approaches that focused on the volume of functional lung receiving ≥20 Gy (AUC, 0.70). Probabilities of grade 3+ RP of 20% and 10% correspond to V20 (percentage of volume receiving ≥20 Gy) to the functional subvolumes of 26.8% and 9.3%, respectively. Imaging-based analysis with the dose-function histogram and nonlinear weighted ventilation values yielded AUCs of 0.66 and 0.67, respectively, when we evaluated the percentage of functionality receiving ≥20 Gy. All dose-function metrics outperformed the traditional dose metrics (mean lung dose, AUC of 0.55). Conclusions A full range of dose-function metrics and functional thresholds was examined. The calculated AUC values for the most predictive functional models occupied a narrow range (0.66-0.70), and all showed notable improvements over AUC from traditional lung dose metrics (0.55). Identifying the combinations most predictive of grade 3+ RP provides valuable data to inform the functional-guided radiation therapy process.

AB - Purpose Four-dimensional (4D) computed tomography (CT) ventilation imaging is increasingly being used to calculate lung ventilation and implement functional-guided radiation therapy in clinical trials. There has been little exhaustive work evaluating which dose-function metrics should be used for treatment planning and plan evaluation. The purpose of our study was to evaluate which dose-function metrics best predict for radiation pneumonitis (RP). Methods and Materials Seventy lung cancer patients who underwent 4D CT imaging and pneumonitis grading were assessed. Pretreatment 4D CT scans of each patient were used to calculate ventilation images. We evaluated 3 types of dose-function metrics that combined the patient's 4D CT ventilation image and treatment planning dose distribution: (1) structure-based approaches; (2) image-based approaches using the dose-function histogram; and (3) nonlinear weighting schemes. Log-likelihood methods were used to generate normal tissue complication probability models predicting grade 3 or higher (ie, grade 3+) pneumonitis for all dose-function schemes. The area under the curve (AUC) was used to assess the predictive power of the models. All techniques were compared with normal tissue complication probability models based on traditional, total lung dose metrics. Results The most predictive models were structure-based approaches that focused on the volume of functional lung receiving ≥20 Gy (AUC, 0.70). Probabilities of grade 3+ RP of 20% and 10% correspond to V20 (percentage of volume receiving ≥20 Gy) to the functional subvolumes of 26.8% and 9.3%, respectively. Imaging-based analysis with the dose-function histogram and nonlinear weighted ventilation values yielded AUCs of 0.66 and 0.67, respectively, when we evaluated the percentage of functionality receiving ≥20 Gy. All dose-function metrics outperformed the traditional dose metrics (mean lung dose, AUC of 0.55). Conclusions A full range of dose-function metrics and functional thresholds was examined. The calculated AUC values for the most predictive functional models occupied a narrow range (0.66-0.70), and all showed notable improvements over AUC from traditional lung dose metrics (0.55). Identifying the combinations most predictive of grade 3+ RP provides valuable data to inform the functional-guided radiation therapy process.

UR - http://www.scopus.com/inward/record.url?scp=85027686227&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85027686227&partnerID=8YFLogxK

U2 - 10.1016/j.ijrobp.2017.03.051

DO - 10.1016/j.ijrobp.2017.03.051

M3 - Article

VL - 99

SP - 202

EP - 209

JO - International Journal of Radiation Oncology Biology Physics

JF - International Journal of Radiation Oncology Biology Physics

SN - 0360-3016

IS - 1

ER -