T1 - Evaluation of Radiological Features of the Posterior Communicating Artery and Their Impact on Efficacy of Saccular Aneurysm Treatment with the Pipeline Embolization Device
T2 - A Case Series Study
AU - Enriquez-Marulanda, Alejandro
AU - Ravindran, Krishnan
AU - Salem, Mohamed M.
AU - Ascanio, Luis C.
AU - Kan, Peter
AU - Srinivasan, Visish M.
AU - Griessenauer, Christoph J.
AU - Schirmer, Clemens M.
AU - Jain, Abhi
AU - Moore, Justin M.
AU - Ogilvy, Christopher S.
AU - Thomas, Ajith J.
AU - Alturki, Abdulrahman Y.
N1 - Publisher Copyright:
© 2019 Elsevier Inc.
PY - 2019/5
Y1 - 2019/5
N2 - Background: Posterior communicating artery segment aneurysms are one of the most frequent intracranial aneurysms. Currently, limited data have described the use of the pipeline embolization device (PED) in these aneurysms. Methods: We conducted a multicenter retrospective review of 3 prospectively collected databases of patients treated with the PED from January 2013 to December 2017. The primary objective was to assess the efficacy and safety of the PED in the treatment of saccular posterior communicating artery (PComA) aneurysms. We also assessed the effect of anatomical variations on the angiographic and clinical outcomes, including the presence of fetal PComA, vessel origin relationship to the aneurysm, and patency after PED placement. Results: We identified 57 patients with 60 saccular aneurysms; Their mean age was 60.5 years, and 49 were female (86.0%). A total of 55 aneurysms (91.7%) were unruptured. The median imaging follow-up duration was 8.5 months. Complete occlusion at the last imaging follow-up study was 84.0%. At the last follow-up examination, 94.5% of patients had a modified Rankin scale score of ≤2. The presence of fetal PComA, origin type, and patency during follow-up did have a significant effect on aneurysm occlusion (P = 0.61, P = 0.40, and P = 0.14, respectively). Conclusions: PED use for treatment of PComA aneurysms resulted in acceptable occlusion rates. The present study did not find that fetal PComA, its origin, or its patency during follow-up had an effect on aneurysm occlusion.
AB - Background: Posterior communicating artery segment aneurysms are one of the most frequent intracranial aneurysms. Currently, limited data have described the use of the pipeline embolization device (PED) in these aneurysms. Methods: We conducted a multicenter retrospective review of 3 prospectively collected databases of patients treated with the PED from January 2013 to December 2017. The primary objective was to assess the efficacy and safety of the PED in the treatment of saccular posterior communicating artery (PComA) aneurysms. We also assessed the effect of anatomical variations on the angiographic and clinical outcomes, including the presence of fetal PComA, vessel origin relationship to the aneurysm, and patency after PED placement. Results: We identified 57 patients with 60 saccular aneurysms; Their mean age was 60.5 years, and 49 were female (86.0%). A total of 55 aneurysms (91.7%) were unruptured. The median imaging follow-up duration was 8.5 months. Complete occlusion at the last imaging follow-up study was 84.0%. At the last follow-up examination, 94.5% of patients had a modified Rankin scale score of ≤2. The presence of fetal PComA, origin type, and patency during follow-up did have a significant effect on aneurysm occlusion (P = 0.61, P = 0.40, and P = 0.14, respectively). Conclusions: PED use for treatment of PComA aneurysms resulted in acceptable occlusion rates. The present study did not find that fetal PComA, its origin, or its patency during follow-up had an effect on aneurysm occlusion.
KW - Anatomy
KW - Flow diversion
KW - Patency
KW - Pipeline embolization device
KW - Posterior communicating artery
UR - http://www.scopus.com/inward/record.url?scp=85062652247&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85062652247&partnerID=8YFLogxK
U2 - 10.1016/j.wneu.2019.01.228
DO - 10.1016/j.wneu.2019.01.228
M3 - Article
C2 - 30771544
AN - SCOPUS:85062652247
SN - 1878-8750
VL - 125
SP - e998-e1007
JO - World Neurosurgery
JF - World Neurosurgery
ER -