Laser Doppler flowmetry in burn wounds

L. Atiles, William Mileski, G. Purdue, J. Hunt, C. Baxter

Research output: Contribution to journalArticle

42 Citations (Scopus)

Abstract

Traditional methods for judgment of burn depth by clinical evaluation of the wound based on appearance and sensation remain in wide use but are subject to individual variation by examiner. In addition to the clinical difficulties with burn wound management, observer dependency of wound assessment complicates clinical trials of burn wound therapy. A laser Doppler flowmeter with a newly designed multichannel probe was used to measure burn wound perfusion as a tool to predict wound outcome. Wounds that healed spontaneously in fewer than 21 days showed higher average perfusion levels than those that required excision and grafting or that were not healed by day 21 after the burn. Laser Doppler flowmetry had a positive predictive value of 100% for nonhealing wounds on postburn days 1 and 3. These data suggest that laser Doppler flowmetry is a potentially useful tool for burn wound assessment.

Original languageEnglish (US)
Pages (from-to)388-393
Number of pages6
JournalJournal of Burn Care and Rehabilitation
Volume16
Issue number4
DOIs
StatePublished - 1995
Externally publishedYes

Fingerprint

Laser-Doppler Flowmetry
Wounds and Injuries
Perfusion
Flowmeters
Lasers
Clinical Trials

ASJC Scopus subject areas

  • Rehabilitation
  • Surgery
  • Nursing(all)
  • Health Professions(all)
  • Emergency Medicine

Cite this

Laser Doppler flowmetry in burn wounds. / Atiles, L.; Mileski, William; Purdue, G.; Hunt, J.; Baxter, C.

In: Journal of Burn Care and Rehabilitation, Vol. 16, No. 4, 1995, p. 388-393.

Research output: Contribution to journalArticle

Atiles, L. ; Mileski, William ; Purdue, G. ; Hunt, J. ; Baxter, C. / Laser Doppler flowmetry in burn wounds. In: Journal of Burn Care and Rehabilitation. 1995 ; Vol. 16, No. 4. pp. 388-393.
@article{a33bb0aa86c8410c841b3321fcb9598e,
title = "Laser Doppler flowmetry in burn wounds",
abstract = "Traditional methods for judgment of burn depth by clinical evaluation of the wound based on appearance and sensation remain in wide use but are subject to individual variation by examiner. In addition to the clinical difficulties with burn wound management, observer dependency of wound assessment complicates clinical trials of burn wound therapy. A laser Doppler flowmeter with a newly designed multichannel probe was used to measure burn wound perfusion as a tool to predict wound outcome. Wounds that healed spontaneously in fewer than 21 days showed higher average perfusion levels than those that required excision and grafting or that were not healed by day 21 after the burn. Laser Doppler flowmetry had a positive predictive value of 100{\%} for nonhealing wounds on postburn days 1 and 3. These data suggest that laser Doppler flowmetry is a potentially useful tool for burn wound assessment.",
author = "L. Atiles and William Mileski and G. Purdue and J. Hunt and C. Baxter",
year = "1995",
doi = "10.1097/00004630-199507000-00003",
language = "English (US)",
volume = "16",
pages = "388--393",
journal = "Journal of Burn Care and Research",
issn = "1559-047X",
publisher = "Lippincott Williams and Wilkins",
number = "4",

}

TY - JOUR

T1 - Laser Doppler flowmetry in burn wounds

AU - Atiles, L.

AU - Mileski, William

AU - Purdue, G.

AU - Hunt, J.

AU - Baxter, C.

PY - 1995

Y1 - 1995

N2 - Traditional methods for judgment of burn depth by clinical evaluation of the wound based on appearance and sensation remain in wide use but are subject to individual variation by examiner. In addition to the clinical difficulties with burn wound management, observer dependency of wound assessment complicates clinical trials of burn wound therapy. A laser Doppler flowmeter with a newly designed multichannel probe was used to measure burn wound perfusion as a tool to predict wound outcome. Wounds that healed spontaneously in fewer than 21 days showed higher average perfusion levels than those that required excision and grafting or that were not healed by day 21 after the burn. Laser Doppler flowmetry had a positive predictive value of 100% for nonhealing wounds on postburn days 1 and 3. These data suggest that laser Doppler flowmetry is a potentially useful tool for burn wound assessment.

AB - Traditional methods for judgment of burn depth by clinical evaluation of the wound based on appearance and sensation remain in wide use but are subject to individual variation by examiner. In addition to the clinical difficulties with burn wound management, observer dependency of wound assessment complicates clinical trials of burn wound therapy. A laser Doppler flowmeter with a newly designed multichannel probe was used to measure burn wound perfusion as a tool to predict wound outcome. Wounds that healed spontaneously in fewer than 21 days showed higher average perfusion levels than those that required excision and grafting or that were not healed by day 21 after the burn. Laser Doppler flowmetry had a positive predictive value of 100% for nonhealing wounds on postburn days 1 and 3. These data suggest that laser Doppler flowmetry is a potentially useful tool for burn wound assessment.

UR - http://www.scopus.com/inward/record.url?scp=0029089878&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0029089878&partnerID=8YFLogxK

U2 - 10.1097/00004630-199507000-00003

DO - 10.1097/00004630-199507000-00003

M3 - Article

VL - 16

SP - 388

EP - 393

JO - Journal of Burn Care and Research

JF - Journal of Burn Care and Research

SN - 1559-047X

IS - 4

ER -