TY - JOUR
T1 - Lumbar puncture during spaceflight
T2 - Operational considerations, constraints, concerns, and limitations
AU - Barr, Yael R.
N1 - Publisher Copyright:
© by the Aerospace Medical Association, Alexandria, VA.
PY - 2014
Y1 - 2014
N2 - Lumbar puncture (LP) is a commonly performed low-risk procedure terrestrially, used diagnostically for evaluation of cerebrospinal fluid (CSF) pressure as well as for collection of CSF for analysis. NASA is investigating noninvasive means for measurement of intracranial pressure (ICP) to assess the potential contribution of elevated intracranial pressures to recently reported changes in astronauts ' visual acuity and eye anatomy, known collectively as the Visual Impairment/Intracranial Pressure risk. However, many of these noninvasive technologies are still under development, have limited clinical validation, are several years away from being ready for in-flight use, or only provide qualitative rather than quantitative ICP values. Therefore, performance of in-flight LPs, as part of crewmember evaluation, has also been considered by NASA. This manuscript summarizes the unique operational considerations, constraints, concerns, and limitations of using traditional LP as an adjunct or as an alternative to noninvasive ICP measurements during spaceflight.
AB - Lumbar puncture (LP) is a commonly performed low-risk procedure terrestrially, used diagnostically for evaluation of cerebrospinal fluid (CSF) pressure as well as for collection of CSF for analysis. NASA is investigating noninvasive means for measurement of intracranial pressure (ICP) to assess the potential contribution of elevated intracranial pressures to recently reported changes in astronauts ' visual acuity and eye anatomy, known collectively as the Visual Impairment/Intracranial Pressure risk. However, many of these noninvasive technologies are still under development, have limited clinical validation, are several years away from being ready for in-flight use, or only provide qualitative rather than quantitative ICP values. Therefore, performance of in-flight LPs, as part of crewmember evaluation, has also been considered by NASA. This manuscript summarizes the unique operational considerations, constraints, concerns, and limitations of using traditional LP as an adjunct or as an alternative to noninvasive ICP measurements during spaceflight.
KW - Astronauts
KW - Intracranial pressure
KW - Microgravity
UR - http://www.scopus.com/inward/record.url?scp=84916598282&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84916598282&partnerID=8YFLogxK
U2 - 10.3357/ASEM.3674.2014
DO - 10.3357/ASEM.3674.2014
M3 - Review article
C2 - 25479263
AN - SCOPUS:84916598282
SN - 0095-6562
VL - 85
SP - 1209
EP - 1213
JO - Aviation Space and Environmental Medicine
JF - Aviation Space and Environmental Medicine
IS - 12
ER -