Modification of the dermacarrier to obtain meshed split skin grafts of different expansion ratios

Peter Dziewulski, A. R. Phipps

Research output: Contribution to journalArticlepeer-review

4 Scopus citations

Abstract

Machine meshing a split skin graft is a valuable technique. Expansion ratios vary depending on the dermacarrier used. We present a method in which different expansion ratios can be obtained using the same dermacarrier.

Original languageEnglish (US)
Pages (from-to)315-317
Number of pages3
JournalBritish Journal of Plastic Surgery
Volume44
Issue number4
DOIs
StatePublished - Jan 1 1991
Externally publishedYes

ASJC Scopus subject areas

  • Surgery
  • Otorhinolaryngology

Fingerprint

Dive into the research topics of 'Modification of the dermacarrier to obtain meshed split skin grafts of different expansion ratios'. Together they form a unique fingerprint.