TY - JOUR
T1 - Optic Nerve Sheath Diameter Point-of-Care Ultrasonography Quality Criteria Checklist
T2 - An International Consensus Statement on Optic Nerve Sheath Diameter Imaging and Measurement∗
AU - Hirzallah, Mohammad I.
AU - Lochner, Piergiorgio
AU - Hafeez, Muhammad Ubaid
AU - Lee, Andrew G.
AU - Krogias, Christos
AU - Dongarwar, Deepa
AU - Hartman, Nicholas D.
AU - Ertl, Michael
AU - Robba, Chiara
AU - Malojcic, Branko
AU - Valaikiene, Jurgita
AU - Sarwal, Aarti
AU - Hakimi, Ryan
AU - Schlachetzki, Felix
N1 - Publisher Copyright:
© 2024 by the Society of Critical Care Medicine and Wolters Kluwer Health, Inc. All Rights Reserved.
PY - 2024/10/1
Y1 - 2024/10/1
N2 - OBJECTIVES: To standardize optic nerve sheath diameter (ONSD) point-of-care ultrasonography (POCUS) and improve its research and clinical utility by developing the ONSD POCUS Quality Criteria Checklist (ONSD POCUS QCC). DESIGN: Three rounds of modified Delphi consensus process and three rounds of asynchronous discussions. SETTING: Online surveys and anonymous asynchronous discussion. SUBJECTS: Expert panelists were identified according to their expertise in ONSD research, publication records, education, and clinical use. A total of 52 panelists participated in the Delphi process. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Three Delphi rounds and three asynchronous discussion rounds generated consensus on quality criteria (QC). This started with 29 QC in addition to other QC proposed by expert panelists. The QC items were categorized into probe selection, safety, body position, imaging, measurement, and research considerations. At the conclusion of the study, 28 QC reached consensus to include in the final ONSD POCUS QCC. These QC were then reorganized, edited, and consolidated into 23 QC that were reviewed and approved by the panelists. CONCLUSIONS: ONSD POCUS QCC standardizes ONSD ultrasound imaging and measurement based on international consensus. This can establish ONSD ultrasound in clinical research and improve its utility in clinical practice.
AB - OBJECTIVES: To standardize optic nerve sheath diameter (ONSD) point-of-care ultrasonography (POCUS) and improve its research and clinical utility by developing the ONSD POCUS Quality Criteria Checklist (ONSD POCUS QCC). DESIGN: Three rounds of modified Delphi consensus process and three rounds of asynchronous discussions. SETTING: Online surveys and anonymous asynchronous discussion. SUBJECTS: Expert panelists were identified according to their expertise in ONSD research, publication records, education, and clinical use. A total of 52 panelists participated in the Delphi process. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Three Delphi rounds and three asynchronous discussion rounds generated consensus on quality criteria (QC). This started with 29 QC in addition to other QC proposed by expert panelists. The QC items were categorized into probe selection, safety, body position, imaging, measurement, and research considerations. At the conclusion of the study, 28 QC reached consensus to include in the final ONSD POCUS QCC. These QC were then reorganized, edited, and consolidated into 23 QC that were reviewed and approved by the panelists. CONCLUSIONS: ONSD POCUS QCC standardizes ONSD ultrasound imaging and measurement based on international consensus. This can establish ONSD ultrasound in clinical research and improve its utility in clinical practice.
KW - consensus
KW - Delphi
KW - intracranial pressure
KW - optic nerve sheath diameter
KW - quality criteria
KW - ultrasound
UR - http://www.scopus.com/inward/record.url?scp=85199049692&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85199049692&partnerID=8YFLogxK
U2 - 10.1097/CCM.0000000000006345
DO - 10.1097/CCM.0000000000006345
M3 - Article
C2 - 38836697
AN - SCOPUS:85199049692
SN - 0090-3493
VL - 52
SP - 1543
EP - 1556
JO - Critical care medicine
JF - Critical care medicine
IS - 10