Oxygen saturation levels in the first 30 minutes of life

M. Terese Verklan, Nikhil S. Padhye, Natasha C. Turner

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Purpose: To report a serendipitous finding from a larger investigation describing physiologic variability of healthy and sick pre- and full-term neonates transitioning to extrauterine life in whom the oxygen arterial saturations rose to 90% very quickly. SUBJECTS: Thirty-four healthy pre- and full-term neonates and 40 sick pre- and full-term neonates. DESIGN: Descriptive, comparative. METHODS: Within the first 15-30 seconds of life, a pulse oximeter probe was placed on the dorsum of the neonate's foot. The signal was uploaded from the Hewlett Packard Viridia cardiopulmonary/oxygen saturation monitor to a data acquisition module at the bedside. Healthcare personnel performed their routine caregiving procedures for the neonate beginning transition to extrauterine life. They were at liberty to administer oxygen when they felt it was clinically necessary. MAIN OUTCOME MEASURES: Oxygen saturation as measured by pulse oximetry. PRINCIPAL RESULTS: Oxygen saturation values reached higher levels much faster for all groups of neonates than what has been previously reported in the literature. CONCLUSIONS: In light of recent controversies regarding oxygen therapy, the practice of randomly administering oxygen to healthy infants at time of delivery should be examined.

Original languageEnglish (US)
Pages (from-to)231-236
Number of pages6
JournalAdvances in Neonatal Care
Volume8
Issue number4
DOIs
StatePublished - Aug 2008
Externally publishedYes

Fingerprint

Oxygen
Newborn Infant
Oximetry
Pulse
Foot
Delivery of Health Care
Therapeutics

Keywords

  • Neonate
  • Oxygen saturation
  • Pulse oximetry
  • Transition to extrauterine life

ASJC Scopus subject areas

  • Pediatrics, Perinatology, and Child Health

Cite this

Oxygen saturation levels in the first 30 minutes of life. / Verklan, M. Terese; Padhye, Nikhil S.; Turner, Natasha C.

In: Advances in Neonatal Care, Vol. 8, No. 4, 08.2008, p. 231-236.

Research output: Contribution to journalArticle

Verklan, M. Terese ; Padhye, Nikhil S. ; Turner, Natasha C. / Oxygen saturation levels in the first 30 minutes of life. In: Advances in Neonatal Care. 2008 ; Vol. 8, No. 4. pp. 231-236.
@article{c03c0528f624411f84c1e454cebb2a1d,
title = "Oxygen saturation levels in the first 30 minutes of life",
abstract = "Purpose: To report a serendipitous finding from a larger investigation describing physiologic variability of healthy and sick pre- and full-term neonates transitioning to extrauterine life in whom the oxygen arterial saturations rose to 90{\%} very quickly. SUBJECTS: Thirty-four healthy pre- and full-term neonates and 40 sick pre- and full-term neonates. DESIGN: Descriptive, comparative. METHODS: Within the first 15-30 seconds of life, a pulse oximeter probe was placed on the dorsum of the neonate's foot. The signal was uploaded from the Hewlett Packard Viridia cardiopulmonary/oxygen saturation monitor to a data acquisition module at the bedside. Healthcare personnel performed their routine caregiving procedures for the neonate beginning transition to extrauterine life. They were at liberty to administer oxygen when they felt it was clinically necessary. MAIN OUTCOME MEASURES: Oxygen saturation as measured by pulse oximetry. PRINCIPAL RESULTS: Oxygen saturation values reached higher levels much faster for all groups of neonates than what has been previously reported in the literature. CONCLUSIONS: In light of recent controversies regarding oxygen therapy, the practice of randomly administering oxygen to healthy infants at time of delivery should be examined.",
keywords = "Neonate, Oxygen saturation, Pulse oximetry, Transition to extrauterine life",
author = "Verklan, {M. Terese} and Padhye, {Nikhil S.} and Turner, {Natasha C.}",
year = "2008",
month = "8",
doi = "10.1097/01.ANC.0000333711.91140.5f",
language = "English (US)",
volume = "8",
pages = "231--236",
journal = "Advances in Neonatal Care",
issn = "1536-0903",
publisher = "Lippincott Williams and Wilkins",
number = "4",

}

TY - JOUR

T1 - Oxygen saturation levels in the first 30 minutes of life

AU - Verklan, M. Terese

AU - Padhye, Nikhil S.

AU - Turner, Natasha C.

PY - 2008/8

Y1 - 2008/8

N2 - Purpose: To report a serendipitous finding from a larger investigation describing physiologic variability of healthy and sick pre- and full-term neonates transitioning to extrauterine life in whom the oxygen arterial saturations rose to 90% very quickly. SUBJECTS: Thirty-four healthy pre- and full-term neonates and 40 sick pre- and full-term neonates. DESIGN: Descriptive, comparative. METHODS: Within the first 15-30 seconds of life, a pulse oximeter probe was placed on the dorsum of the neonate's foot. The signal was uploaded from the Hewlett Packard Viridia cardiopulmonary/oxygen saturation monitor to a data acquisition module at the bedside. Healthcare personnel performed their routine caregiving procedures for the neonate beginning transition to extrauterine life. They were at liberty to administer oxygen when they felt it was clinically necessary. MAIN OUTCOME MEASURES: Oxygen saturation as measured by pulse oximetry. PRINCIPAL RESULTS: Oxygen saturation values reached higher levels much faster for all groups of neonates than what has been previously reported in the literature. CONCLUSIONS: In light of recent controversies regarding oxygen therapy, the practice of randomly administering oxygen to healthy infants at time of delivery should be examined.

AB - Purpose: To report a serendipitous finding from a larger investigation describing physiologic variability of healthy and sick pre- and full-term neonates transitioning to extrauterine life in whom the oxygen arterial saturations rose to 90% very quickly. SUBJECTS: Thirty-four healthy pre- and full-term neonates and 40 sick pre- and full-term neonates. DESIGN: Descriptive, comparative. METHODS: Within the first 15-30 seconds of life, a pulse oximeter probe was placed on the dorsum of the neonate's foot. The signal was uploaded from the Hewlett Packard Viridia cardiopulmonary/oxygen saturation monitor to a data acquisition module at the bedside. Healthcare personnel performed their routine caregiving procedures for the neonate beginning transition to extrauterine life. They were at liberty to administer oxygen when they felt it was clinically necessary. MAIN OUTCOME MEASURES: Oxygen saturation as measured by pulse oximetry. PRINCIPAL RESULTS: Oxygen saturation values reached higher levels much faster for all groups of neonates than what has been previously reported in the literature. CONCLUSIONS: In light of recent controversies regarding oxygen therapy, the practice of randomly administering oxygen to healthy infants at time of delivery should be examined.

KW - Neonate

KW - Oxygen saturation

KW - Pulse oximetry

KW - Transition to extrauterine life

UR - http://www.scopus.com/inward/record.url?scp=58149193478&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=58149193478&partnerID=8YFLogxK

U2 - 10.1097/01.ANC.0000333711.91140.5f

DO - 10.1097/01.ANC.0000333711.91140.5f

M3 - Article

C2 - 18690084

AN - SCOPUS:58149193478

VL - 8

SP - 231

EP - 236

JO - Advances in Neonatal Care

JF - Advances in Neonatal Care

SN - 1536-0903

IS - 4

ER -