Percutaneous closure of coronary pulmonary arterial fistula using catheterization laboratory trash

Vijay Kumar Trehan, Ramesh Arora, Saibal Mukhopadhyay, Girish M. Nair, Umamahesh Rangasetty, Jamal Yusuf, Chandrashekhar

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

We report a case of coronary pulmonary arterial fistula that was successfully occluded by packing the fistula with thrombogenic floppy tips of used percutaneous transluminal coronary angioplasty guidewires instead of conventional steel coils.

Original languageEnglish (US)
Pages (from-to)49-51
Number of pages3
JournalCatheterization and Cardiovascular Interventions
Volume59
Issue number1
DOIs
StatePublished - May 1 2003
Externally publishedYes

Fingerprint

Catheterization
Fistula
Lung
Coronary Balloon Angioplasty
Steel

Keywords

  • Coil embolization
  • Coronary fistula
  • PTCA guidewires

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Radiology Nuclear Medicine and imaging

Cite this

Percutaneous closure of coronary pulmonary arterial fistula using catheterization laboratory trash. / Trehan, Vijay Kumar; Arora, Ramesh; Mukhopadhyay, Saibal; Nair, Girish M.; Rangasetty, Umamahesh; Yusuf, Jamal; Chandrashekhar.

In: Catheterization and Cardiovascular Interventions, Vol. 59, No. 1, 01.05.2003, p. 49-51.

Research output: Contribution to journalArticle

Trehan, Vijay Kumar ; Arora, Ramesh ; Mukhopadhyay, Saibal ; Nair, Girish M. ; Rangasetty, Umamahesh ; Yusuf, Jamal ; Chandrashekhar. / Percutaneous closure of coronary pulmonary arterial fistula using catheterization laboratory trash. In: Catheterization and Cardiovascular Interventions. 2003 ; Vol. 59, No. 1. pp. 49-51.
@article{61b64071d83740019e3f5a74d6f311aa,
title = "Percutaneous closure of coronary pulmonary arterial fistula using catheterization laboratory trash",
abstract = "We report a case of coronary pulmonary arterial fistula that was successfully occluded by packing the fistula with thrombogenic floppy tips of used percutaneous transluminal coronary angioplasty guidewires instead of conventional steel coils.",
keywords = "Coil embolization, Coronary fistula, PTCA guidewires",
author = "Trehan, {Vijay Kumar} and Ramesh Arora and Saibal Mukhopadhyay and Nair, {Girish M.} and Umamahesh Rangasetty and Jamal Yusuf and Chandrashekhar",
year = "2003",
month = "5",
day = "1",
doi = "10.1002/ccd.10469",
language = "English (US)",
volume = "59",
pages = "49--51",
journal = "Catheterization and Cardiovascular Interventions",
issn = "1522-1946",
publisher = "Wiley-Liss Inc.",
number = "1",

}

TY - JOUR

T1 - Percutaneous closure of coronary pulmonary arterial fistula using catheterization laboratory trash

AU - Trehan, Vijay Kumar

AU - Arora, Ramesh

AU - Mukhopadhyay, Saibal

AU - Nair, Girish M.

AU - Rangasetty, Umamahesh

AU - Yusuf, Jamal

AU - Chandrashekhar,

PY - 2003/5/1

Y1 - 2003/5/1

N2 - We report a case of coronary pulmonary arterial fistula that was successfully occluded by packing the fistula with thrombogenic floppy tips of used percutaneous transluminal coronary angioplasty guidewires instead of conventional steel coils.

AB - We report a case of coronary pulmonary arterial fistula that was successfully occluded by packing the fistula with thrombogenic floppy tips of used percutaneous transluminal coronary angioplasty guidewires instead of conventional steel coils.

KW - Coil embolization

KW - Coronary fistula

KW - PTCA guidewires

UR - http://www.scopus.com/inward/record.url?scp=0037624987&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0037624987&partnerID=8YFLogxK

U2 - 10.1002/ccd.10469

DO - 10.1002/ccd.10469

M3 - Article

VL - 59

SP - 49

EP - 51

JO - Catheterization and Cardiovascular Interventions

JF - Catheterization and Cardiovascular Interventions

SN - 1522-1946

IS - 1

ER -