Percutaneous intervention for recurrent aortic insufficiency in a patient with a left ventricular assist device and a centrally oversewn aortic valve

Raymond Bietry, Leora B. Balsam, Muhamed Saric, Doff B. McElhinney, Stuart Katz, Abelardo DeAnda, Alex Reyentovich

Research output: Contribution to journalArticle

3 Citations (Scopus)
Original languageEnglish (US)
JournalCirculation: Heart Failure
Volume6
Issue number4
DOIs
StatePublished - Jul 2013
Externally publishedYes

Fingerprint

Prosthesis Design
Septal Occluder Device
Heart-Assist Devices
Aortic Valve Insufficiency
Cardiogenic Shock
Transesophageal Echocardiography
Aortic Valve
Echocardiography
Recurrence

Keywords

  • 3-dimensional
  • Amplatzer device
  • Aortic valve regurgitation
  • Echocardiography
  • Left ventricular assist device

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Medicine(all)

Cite this

Percutaneous intervention for recurrent aortic insufficiency in a patient with a left ventricular assist device and a centrally oversewn aortic valve. / Bietry, Raymond; Balsam, Leora B.; Saric, Muhamed; McElhinney, Doff B.; Katz, Stuart; DeAnda, Abelardo; Reyentovich, Alex.

In: Circulation: Heart Failure, Vol. 6, No. 4, 07.2013.

Research output: Contribution to journalArticle

Bietry, Raymond ; Balsam, Leora B. ; Saric, Muhamed ; McElhinney, Doff B. ; Katz, Stuart ; DeAnda, Abelardo ; Reyentovich, Alex. / Percutaneous intervention for recurrent aortic insufficiency in a patient with a left ventricular assist device and a centrally oversewn aortic valve. In: Circulation: Heart Failure. 2013 ; Vol. 6, No. 4.
@article{9e1ebb38843843dc8177a0514551d63b,
title = "Percutaneous intervention for recurrent aortic insufficiency in a patient with a left ventricular assist device and a centrally oversewn aortic valve",
keywords = "3-dimensional, Amplatzer device, Aortic valve regurgitation, Echocardiography, Left ventricular assist device",
author = "Raymond Bietry and Balsam, {Leora B.} and Muhamed Saric and McElhinney, {Doff B.} and Stuart Katz and Abelardo DeAnda and Alex Reyentovich",
year = "2013",
month = "7",
doi = "10.1161/CIRCHEARTFAILURE.113.000301",
language = "English (US)",
volume = "6",
journal = "Circulation: Heart Failure",
issn = "1941-3297",
publisher = "Lippincott Williams and Wilkins",
number = "4",

}

TY - JOUR

T1 - Percutaneous intervention for recurrent aortic insufficiency in a patient with a left ventricular assist device and a centrally oversewn aortic valve

AU - Bietry, Raymond

AU - Balsam, Leora B.

AU - Saric, Muhamed

AU - McElhinney, Doff B.

AU - Katz, Stuart

AU - DeAnda, Abelardo

AU - Reyentovich, Alex

PY - 2013/7

Y1 - 2013/7

KW - 3-dimensional

KW - Amplatzer device

KW - Aortic valve regurgitation

KW - Echocardiography

KW - Left ventricular assist device

UR - http://www.scopus.com/inward/record.url?scp=84884720305&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84884720305&partnerID=8YFLogxK

U2 - 10.1161/CIRCHEARTFAILURE.113.000301

DO - 10.1161/CIRCHEARTFAILURE.113.000301

M3 - Article

C2 - 23861507

AN - SCOPUS:84884720305

VL - 6

JO - Circulation: Heart Failure

JF - Circulation: Heart Failure

SN - 1941-3297

IS - 4

ER -