Abstract
PURPOSE: To evaluate the feasibility, safety, and workflow of the development and prospective implementation of magnetic resonance-guided position-location tracking technology (MR-tracking [MRT]) for interstitial gynecologic brachytherapy. METHODS AND MATERIALS: Between 2018 and 2023, patients undergoing template-based (Syed/Neblett) interstitial brachytherapy were included in the analysis. The 2 cohorts for analysis were (1) prospectively enrolled patients who received MRT for real-time visualization, and (2) standard procedure implants performed without MRT technology. The 2 cohorts were compared for overall procedural time with an ad hoc inferiority analysis, and implant quality was assessed by the resultant clinically delivered dosimetry with a Student's t test. RESULTS: Eighteen (18) patients who consented to treatment with MRT visualization were compared to a cohort of 62 patients undergoing standard interstitial brachytherapy. The MRT system was successfully used without interruption from device-related events in all 18 patients. The mean (standard deviation) procedure time was 96 (±27) min and 100 (±26) min for the MRT and standard implants, supporting the noninferiority conclusion of the MRT implants (p = 0.03). For the patient subgroup including primary vaginal or recurrent endometrial without a uterus, we reported significantly improved clinical target volume (CTV) coverage (p = 0.02) for the MRT cohort, (CTV D90 = 75.2 Gy) compared to the standard procedure cohort (CTV D90 = 66.4 Gy), suggesting the physician was able to better target the tumor volume during needle insertion. Differences in organ-at-risk doses were not statistically significant. CONCLUSIONS: The prospective study establishes the feasibility of MRT integration with the successful demonstration of device reliability in a complex clinical setting. The integration of MRT as an investigational technology did not negatively impact overall procedure time and may have had a positive effect on resultant dosimetry for a subgroup of patients. Future clinical investigations should include prospective use of the technology in a matched-cohort trial.
| Original language | English (US) |
|---|---|
| Pages (from-to) | 741-748 |
| Number of pages | 8 |
| Journal | Brachytherapy |
| Volume | 25 |
| Issue number | 5 |
| DOIs | |
| State | Published - Sep 1 2026 |
| Externally published | Yes |
Keywords
- Brachytherapy
- Feasibility
- Gynecologic
- Image-guided
- Interstitial
- MRI
- Prospective
- Safety
- Tracking
- Trial
ASJC Scopus subject areas
- Radiology Nuclear Medicine and imaging
- Oncology
Fingerprint
Dive into the research topics of 'Prospective operational feasibility, safety, and workflow of magnetic resonance-guided tracking technology for interstitial gynecologic brachytherapy'. Together they form a unique fingerprint.Cite this
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS