Rapid and repeated blood sampling in the conscious laboratory rat

a new technique.

O. E. Winsett, Courtney Townsend, J. C. Thompson

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

A method for obtaining repeated blood samples from conscious rats by translumbar vena cava puncture is presented. Studies performed at laparotomy enabled us to select a 5/8-in., 25-gauge needle as the ideal instrument for aspirating blood. The awake rat is held prone by an assistant and the needle inserted at the level of the first lumbar vertebra in the coronal plane at an angle of 45 degrees from the vertical. We performed the procedure 350 times in 30 rats (100-300 g) at weekly intervals for 8 wk. Each time, we have obtained 2 ml of blood. The time required for obtaining 30 samples is 15-20 min. There have been no complications and only three deaths (mortality rate, 0.9% per puncture); in all three instances the rats jerked free, lacerating the vena cava. The procedure has been performed in guinea pigs and hamsters, with equal ease, without morbidity or mortality. This new technique permits rapid, atraumatic, repeated samplings from awake animals with no morbidity and minimal mortality.

Original languageEnglish (US)
JournalThe American journal of physiology
Volume249
Issue number1 Pt 1
StatePublished - Jul 1985

Fingerprint

Venae Cavae
Mortality
Punctures
Needles
Morbidity
Lumbar Vertebrae
Cricetinae
Laparotomy
Guinea Pigs

ASJC Scopus subject areas

  • Medicine(all)

Cite this

Rapid and repeated blood sampling in the conscious laboratory rat : a new technique. / Winsett, O. E.; Townsend, Courtney; Thompson, J. C.

In: The American journal of physiology, Vol. 249, No. 1 Pt 1, 07.1985.

Research output: Contribution to journalArticle

@article{058f5d62c80c4f7ea160d35700f7e06b,
title = "Rapid and repeated blood sampling in the conscious laboratory rat: a new technique.",
abstract = "A method for obtaining repeated blood samples from conscious rats by translumbar vena cava puncture is presented. Studies performed at laparotomy enabled us to select a 5/8-in., 25-gauge needle as the ideal instrument for aspirating blood. The awake rat is held prone by an assistant and the needle inserted at the level of the first lumbar vertebra in the coronal plane at an angle of 45 degrees from the vertical. We performed the procedure 350 times in 30 rats (100-300 g) at weekly intervals for 8 wk. Each time, we have obtained 2 ml of blood. The time required for obtaining 30 samples is 15-20 min. There have been no complications and only three deaths (mortality rate, 0.9{\%} per puncture); in all three instances the rats jerked free, lacerating the vena cava. The procedure has been performed in guinea pigs and hamsters, with equal ease, without morbidity or mortality. This new technique permits rapid, atraumatic, repeated samplings from awake animals with no morbidity and minimal mortality.",
author = "Winsett, {O. E.} and Courtney Townsend and Thompson, {J. C.}",
year = "1985",
month = "7",
language = "English (US)",
volume = "249",
journal = "American Journal of Physiology - Endocrinology and Metabolism",
issn = "0193-1849",
publisher = "American Physiological Society",
number = "1 Pt 1",

}

TY - JOUR

T1 - Rapid and repeated blood sampling in the conscious laboratory rat

T2 - a new technique.

AU - Winsett, O. E.

AU - Townsend, Courtney

AU - Thompson, J. C.

PY - 1985/7

Y1 - 1985/7

N2 - A method for obtaining repeated blood samples from conscious rats by translumbar vena cava puncture is presented. Studies performed at laparotomy enabled us to select a 5/8-in., 25-gauge needle as the ideal instrument for aspirating blood. The awake rat is held prone by an assistant and the needle inserted at the level of the first lumbar vertebra in the coronal plane at an angle of 45 degrees from the vertical. We performed the procedure 350 times in 30 rats (100-300 g) at weekly intervals for 8 wk. Each time, we have obtained 2 ml of blood. The time required for obtaining 30 samples is 15-20 min. There have been no complications and only three deaths (mortality rate, 0.9% per puncture); in all three instances the rats jerked free, lacerating the vena cava. The procedure has been performed in guinea pigs and hamsters, with equal ease, without morbidity or mortality. This new technique permits rapid, atraumatic, repeated samplings from awake animals with no morbidity and minimal mortality.

AB - A method for obtaining repeated blood samples from conscious rats by translumbar vena cava puncture is presented. Studies performed at laparotomy enabled us to select a 5/8-in., 25-gauge needle as the ideal instrument for aspirating blood. The awake rat is held prone by an assistant and the needle inserted at the level of the first lumbar vertebra in the coronal plane at an angle of 45 degrees from the vertical. We performed the procedure 350 times in 30 rats (100-300 g) at weekly intervals for 8 wk. Each time, we have obtained 2 ml of blood. The time required for obtaining 30 samples is 15-20 min. There have been no complications and only three deaths (mortality rate, 0.9% per puncture); in all three instances the rats jerked free, lacerating the vena cava. The procedure has been performed in guinea pigs and hamsters, with equal ease, without morbidity or mortality. This new technique permits rapid, atraumatic, repeated samplings from awake animals with no morbidity and minimal mortality.

UR - http://www.scopus.com/inward/record.url?scp=17544393915&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=17544393915&partnerID=8YFLogxK

M3 - Article

VL - 249

JO - American Journal of Physiology - Endocrinology and Metabolism

JF - American Journal of Physiology - Endocrinology and Metabolism

SN - 0193-1849

IS - 1 Pt 1

ER -