TY - JOUR
T1 - Real-time three-dimensional dobutamine stress echocardiography in assessment of ischemia
T2 - Comparison with two-dimensional dobutamine stress echocardiography
AU - Ahmad, Masood
AU - McCulloch, Marti
AU - Abreo, Gerard
AU - Runge, Marschall
PY - 2001/4/1
Y1 - 2001/4/1
N2 - OBJECTIVES: This study was designed to test the feasibility and efficacy of using real-time three-dimensional echocardiography (RT-3D) to detect ischemia during dobutamine-induced stress (DSE) and compares the results with conventional two-dimensional echocardiography (2D). BACKGROUND: Real-time three-dimensional echocardiography, a novel imaging technique, offers rapid acquisition with multiple simultaneous views of the left ventricle (LV). These features make it attractive for application during stress. METHODS: Of 279 consecutive patients screened for image quality by 2D, 253 patients with adequate images underwent RT-3D and 2D within 30 s of each other at baseline and at peak DSE. RESULTS: Real-time three-dimensional echocardiography and 2D showed good concordance in detection of abnormal LV wall motion at baseline (84%: Kappa = 0.59) and at peak DSE (88.9%: Kappa = 0.72). Left ventricular wall motion scores were similar at baseline and peak DSE using both techniques. Interobserver agreements for detection of ischemia at peak DSE were superior for RT-3D, 92.7% compared with 84.6% for 2D (p < 0.05). Mean scanning time at peak stress by RT-3D in 50 randomly selected patients was shorter, 27.4 ± 10.7 s compared with 62.4 ± 20.1 s by 2D (p < 0.0001). In 90 patients with coronary angiograms, RT-3D had a sensitivity of 87.9% in the detection of coronary artery disease (CAD) compared with 79.3% by 2D. CONCLUSIONS: Real-time three-dimensional dobutamine stress echocardiography is feasible and sensitive in the detection of CAD. The procedure offers shorter scanning time, superior interobserver agreements and unique new views of the LV.
AB - OBJECTIVES: This study was designed to test the feasibility and efficacy of using real-time three-dimensional echocardiography (RT-3D) to detect ischemia during dobutamine-induced stress (DSE) and compares the results with conventional two-dimensional echocardiography (2D). BACKGROUND: Real-time three-dimensional echocardiography, a novel imaging technique, offers rapid acquisition with multiple simultaneous views of the left ventricle (LV). These features make it attractive for application during stress. METHODS: Of 279 consecutive patients screened for image quality by 2D, 253 patients with adequate images underwent RT-3D and 2D within 30 s of each other at baseline and at peak DSE. RESULTS: Real-time three-dimensional echocardiography and 2D showed good concordance in detection of abnormal LV wall motion at baseline (84%: Kappa = 0.59) and at peak DSE (88.9%: Kappa = 0.72). Left ventricular wall motion scores were similar at baseline and peak DSE using both techniques. Interobserver agreements for detection of ischemia at peak DSE were superior for RT-3D, 92.7% compared with 84.6% for 2D (p < 0.05). Mean scanning time at peak stress by RT-3D in 50 randomly selected patients was shorter, 27.4 ± 10.7 s compared with 62.4 ± 20.1 s by 2D (p < 0.0001). In 90 patients with coronary angiograms, RT-3D had a sensitivity of 87.9% in the detection of coronary artery disease (CAD) compared with 79.3% by 2D. CONCLUSIONS: Real-time three-dimensional dobutamine stress echocardiography is feasible and sensitive in the detection of CAD. The procedure offers shorter scanning time, superior interobserver agreements and unique new views of the LV.
UR - http://www.scopus.com/inward/record.url?scp=0035312558&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0035312558&partnerID=8YFLogxK
U2 - 10.1016/S0735-1097(01)01159-7
DO - 10.1016/S0735-1097(01)01159-7
M3 - Article
C2 - 11300439
AN - SCOPUS:0035312558
SN - 0735-1097
VL - 37
SP - 1303
EP - 1309
JO - Journal of the American College of Cardiology
JF - Journal of the American College of Cardiology
IS - 5
ER -