Relationship of intraventricular hemorrhage or death with the level of umbilical artery catheter placement

A multicenter randomized clinical trial

Michael Malloy, G. Cutter, S. Shannon, W. Carlo, N. Shenker, R. McClead, Karen Shattuck, Carol Richardson, B. Bloom, P. Delmore, A. Pramanik, J. Rowell, D. Clark, B. Barkemeyer, M. Devoe, T. N K Raju, O. Aldana, S. Lawrence, K. Kanarek

Research output: Contribution to journalArticle

23 Citations (Scopus)

Abstract

Umbilical artery catheters are frequently used in the care of very low birth weight neonates to monitor arterial blood gas values. Historically, catheters with the tip placed low, in the abdominal aorta, have been associated with an increased risk of peripheral vascular complications. Recently, a report suggested that catheters placed high, in the thoracic aorta, were associated with an increased risk of intraventricular hemorrhage. To determine whether there is an association between the placement of an umbilical artery catheter high, in the thoracic aorta, and the occurrence of intraventricular hemorrhage (grades II through IV) or death within the first 5 days of life, a multicenter randomized trial was conducted. Nine hundred seventy neonates weighing 500 through 1499 g were randomly assigned to receive either high catheters, in the thoracic aorta closest to the sixth to eight thoracic vertebra, or low catheters, in the abdominal aorta closest to the third to fifth lumbar vertebra. The incidence of the primary outcome (intraventricular hemorrhage grades II through IV and/or death) was 25.8% among newborns with high catheters and 23.1% in those with low catheters (relative risk = 1.12, 95% confidence interval = 0.89, 1.39). However, a significant interaction was observed between the level of catheter placement and birth weight for neonates weighing 750 through 999 g and those weighing 1000 through 1499 g. The subgroup of neonates weighing 750 to 1000 g had a relative risk of the primary outcome of 0.72 (95% confidence interval = 0.49, 1.07), while those weighing 1000 through 1499 g had a relative risk of 2.02 (1.21, 2.36). The prevalence of peripheral vascular complications was 26.6% among neonates with low catheters compared with 16.0% among those with high catheters (relative risk = 1.66, 95% confidence interval = 1.30, 2.13). It is concluded that the risk for intraventricular hemorrhage (grades II through IV) and/or death among neonates weighing 500 through 1499 g with high catheters is not increased. Catheters placed low in the aorta, however, carry an increased risk of peripheral vascular complications. The observation that birth weight modifies the effect of catheter placement on the primary outcome must be cautiously interpreted because of the dangers of chance observations inherent in subgroup analyses.

Original languageEnglish (US)
Pages (from-to)881-887
Number of pages7
JournalPediatrics
Volume90
Issue number6
StatePublished - 1992

Fingerprint

Umbilical Arteries
Catheters
Randomized Controlled Trials
Hemorrhage
Newborn Infant
Thoracic Aorta
Blood Vessels
Abdominal Aorta
Confidence Intervals
Birth Weight
Thoracic Vertebrae
Lumbar Vertebrae
Very Low Birth Weight Infant
Multicenter Studies
Aorta

Keywords

  • catheter
  • intraventricular hemorrhage
  • neonatal mortality
  • umbilical artery
  • very low birth weight neonates

ASJC Scopus subject areas

  • Pediatrics, Perinatology, and Child Health

Cite this

Relationship of intraventricular hemorrhage or death with the level of umbilical artery catheter placement : A multicenter randomized clinical trial. / Malloy, Michael; Cutter, G.; Shannon, S.; Carlo, W.; Shenker, N.; McClead, R.; Shattuck, Karen; Richardson, Carol; Bloom, B.; Delmore, P.; Pramanik, A.; Rowell, J.; Clark, D.; Barkemeyer, B.; Devoe, M.; Raju, T. N K; Aldana, O.; Lawrence, S.; Kanarek, K.

In: Pediatrics, Vol. 90, No. 6, 1992, p. 881-887.

Research output: Contribution to journalArticle

Malloy, M, Cutter, G, Shannon, S, Carlo, W, Shenker, N, McClead, R, Shattuck, K, Richardson, C, Bloom, B, Delmore, P, Pramanik, A, Rowell, J, Clark, D, Barkemeyer, B, Devoe, M, Raju, TNK, Aldana, O, Lawrence, S & Kanarek, K 1992, 'Relationship of intraventricular hemorrhage or death with the level of umbilical artery catheter placement: A multicenter randomized clinical trial', Pediatrics, vol. 90, no. 6, pp. 881-887.
Malloy, Michael ; Cutter, G. ; Shannon, S. ; Carlo, W. ; Shenker, N. ; McClead, R. ; Shattuck, Karen ; Richardson, Carol ; Bloom, B. ; Delmore, P. ; Pramanik, A. ; Rowell, J. ; Clark, D. ; Barkemeyer, B. ; Devoe, M. ; Raju, T. N K ; Aldana, O. ; Lawrence, S. ; Kanarek, K. / Relationship of intraventricular hemorrhage or death with the level of umbilical artery catheter placement : A multicenter randomized clinical trial. In: Pediatrics. 1992 ; Vol. 90, No. 6. pp. 881-887.
@article{a2fd11c24f1e4a17819fde6d1675f894,
title = "Relationship of intraventricular hemorrhage or death with the level of umbilical artery catheter placement: A multicenter randomized clinical trial",
abstract = "Umbilical artery catheters are frequently used in the care of very low birth weight neonates to monitor arterial blood gas values. Historically, catheters with the tip placed low, in the abdominal aorta, have been associated with an increased risk of peripheral vascular complications. Recently, a report suggested that catheters placed high, in the thoracic aorta, were associated with an increased risk of intraventricular hemorrhage. To determine whether there is an association between the placement of an umbilical artery catheter high, in the thoracic aorta, and the occurrence of intraventricular hemorrhage (grades II through IV) or death within the first 5 days of life, a multicenter randomized trial was conducted. Nine hundred seventy neonates weighing 500 through 1499 g were randomly assigned to receive either high catheters, in the thoracic aorta closest to the sixth to eight thoracic vertebra, or low catheters, in the abdominal aorta closest to the third to fifth lumbar vertebra. The incidence of the primary outcome (intraventricular hemorrhage grades II through IV and/or death) was 25.8{\%} among newborns with high catheters and 23.1{\%} in those with low catheters (relative risk = 1.12, 95{\%} confidence interval = 0.89, 1.39). However, a significant interaction was observed between the level of catheter placement and birth weight for neonates weighing 750 through 999 g and those weighing 1000 through 1499 g. The subgroup of neonates weighing 750 to 1000 g had a relative risk of the primary outcome of 0.72 (95{\%} confidence interval = 0.49, 1.07), while those weighing 1000 through 1499 g had a relative risk of 2.02 (1.21, 2.36). The prevalence of peripheral vascular complications was 26.6{\%} among neonates with low catheters compared with 16.0{\%} among those with high catheters (relative risk = 1.66, 95{\%} confidence interval = 1.30, 2.13). It is concluded that the risk for intraventricular hemorrhage (grades II through IV) and/or death among neonates weighing 500 through 1499 g with high catheters is not increased. Catheters placed low in the aorta, however, carry an increased risk of peripheral vascular complications. The observation that birth weight modifies the effect of catheter placement on the primary outcome must be cautiously interpreted because of the dangers of chance observations inherent in subgroup analyses.",
keywords = "catheter, intraventricular hemorrhage, neonatal mortality, umbilical artery, very low birth weight neonates",
author = "Michael Malloy and G. Cutter and S. Shannon and W. Carlo and N. Shenker and R. McClead and Karen Shattuck and Carol Richardson and B. Bloom and P. Delmore and A. Pramanik and J. Rowell and D. Clark and B. Barkemeyer and M. Devoe and Raju, {T. N K} and O. Aldana and S. Lawrence and K. Kanarek",
year = "1992",
language = "English (US)",
volume = "90",
pages = "881--887",
journal = "Pediatrics",
issn = "0031-4005",
publisher = "American Academy of Pediatrics",
number = "6",

}

TY - JOUR

T1 - Relationship of intraventricular hemorrhage or death with the level of umbilical artery catheter placement

T2 - A multicenter randomized clinical trial

AU - Malloy, Michael

AU - Cutter, G.

AU - Shannon, S.

AU - Carlo, W.

AU - Shenker, N.

AU - McClead, R.

AU - Shattuck, Karen

AU - Richardson, Carol

AU - Bloom, B.

AU - Delmore, P.

AU - Pramanik, A.

AU - Rowell, J.

AU - Clark, D.

AU - Barkemeyer, B.

AU - Devoe, M.

AU - Raju, T. N K

AU - Aldana, O.

AU - Lawrence, S.

AU - Kanarek, K.

PY - 1992

Y1 - 1992

N2 - Umbilical artery catheters are frequently used in the care of very low birth weight neonates to monitor arterial blood gas values. Historically, catheters with the tip placed low, in the abdominal aorta, have been associated with an increased risk of peripheral vascular complications. Recently, a report suggested that catheters placed high, in the thoracic aorta, were associated with an increased risk of intraventricular hemorrhage. To determine whether there is an association between the placement of an umbilical artery catheter high, in the thoracic aorta, and the occurrence of intraventricular hemorrhage (grades II through IV) or death within the first 5 days of life, a multicenter randomized trial was conducted. Nine hundred seventy neonates weighing 500 through 1499 g were randomly assigned to receive either high catheters, in the thoracic aorta closest to the sixth to eight thoracic vertebra, or low catheters, in the abdominal aorta closest to the third to fifth lumbar vertebra. The incidence of the primary outcome (intraventricular hemorrhage grades II through IV and/or death) was 25.8% among newborns with high catheters and 23.1% in those with low catheters (relative risk = 1.12, 95% confidence interval = 0.89, 1.39). However, a significant interaction was observed between the level of catheter placement and birth weight for neonates weighing 750 through 999 g and those weighing 1000 through 1499 g. The subgroup of neonates weighing 750 to 1000 g had a relative risk of the primary outcome of 0.72 (95% confidence interval = 0.49, 1.07), while those weighing 1000 through 1499 g had a relative risk of 2.02 (1.21, 2.36). The prevalence of peripheral vascular complications was 26.6% among neonates with low catheters compared with 16.0% among those with high catheters (relative risk = 1.66, 95% confidence interval = 1.30, 2.13). It is concluded that the risk for intraventricular hemorrhage (grades II through IV) and/or death among neonates weighing 500 through 1499 g with high catheters is not increased. Catheters placed low in the aorta, however, carry an increased risk of peripheral vascular complications. The observation that birth weight modifies the effect of catheter placement on the primary outcome must be cautiously interpreted because of the dangers of chance observations inherent in subgroup analyses.

AB - Umbilical artery catheters are frequently used in the care of very low birth weight neonates to monitor arterial blood gas values. Historically, catheters with the tip placed low, in the abdominal aorta, have been associated with an increased risk of peripheral vascular complications. Recently, a report suggested that catheters placed high, in the thoracic aorta, were associated with an increased risk of intraventricular hemorrhage. To determine whether there is an association between the placement of an umbilical artery catheter high, in the thoracic aorta, and the occurrence of intraventricular hemorrhage (grades II through IV) or death within the first 5 days of life, a multicenter randomized trial was conducted. Nine hundred seventy neonates weighing 500 through 1499 g were randomly assigned to receive either high catheters, in the thoracic aorta closest to the sixth to eight thoracic vertebra, or low catheters, in the abdominal aorta closest to the third to fifth lumbar vertebra. The incidence of the primary outcome (intraventricular hemorrhage grades II through IV and/or death) was 25.8% among newborns with high catheters and 23.1% in those with low catheters (relative risk = 1.12, 95% confidence interval = 0.89, 1.39). However, a significant interaction was observed between the level of catheter placement and birth weight for neonates weighing 750 through 999 g and those weighing 1000 through 1499 g. The subgroup of neonates weighing 750 to 1000 g had a relative risk of the primary outcome of 0.72 (95% confidence interval = 0.49, 1.07), while those weighing 1000 through 1499 g had a relative risk of 2.02 (1.21, 2.36). The prevalence of peripheral vascular complications was 26.6% among neonates with low catheters compared with 16.0% among those with high catheters (relative risk = 1.66, 95% confidence interval = 1.30, 2.13). It is concluded that the risk for intraventricular hemorrhage (grades II through IV) and/or death among neonates weighing 500 through 1499 g with high catheters is not increased. Catheters placed low in the aorta, however, carry an increased risk of peripheral vascular complications. The observation that birth weight modifies the effect of catheter placement on the primary outcome must be cautiously interpreted because of the dangers of chance observations inherent in subgroup analyses.

KW - catheter

KW - intraventricular hemorrhage

KW - neonatal mortality

KW - umbilical artery

KW - very low birth weight neonates

UR - http://www.scopus.com/inward/record.url?scp=0026474630&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0026474630&partnerID=8YFLogxK

M3 - Article

VL - 90

SP - 881

EP - 887

JO - Pediatrics

JF - Pediatrics

SN - 0031-4005

IS - 6

ER -