Resolution of 90 nm (λ/5) in an optical transmission microscope with an annular condenser

Arnold Vainrub, Oleg Pustovyy, Vitaly Vodyanoy

    Research output: Contribution to journalArticle

    89 Citations (Scopus)

    Abstract

    Resolution of 90 nm was achieved with a research microscope simply by replacing the standard bright-field condenser with a homebuilt illumination system with a cardioid annular condenser. Diffraction gratings with 100 nm width lines as well as less than 100 nm size features of different-shaped objects were clearly visible on a calibrated microscope test slide. The resolution increase results from a known narrower diffraction pattern in coherent illumination for the annular aperture compared with the circular aperture. This explanation is supported by an excellent accord of calculated and measured diffraction patterns for a 50 nm radius disk.

    Original languageEnglish (US)
    Pages (from-to)2855-2857
    Number of pages3
    JournalOptics Letters
    Volume31
    Issue number19
    DOIs
    StatePublished - Oct 1 2006

    Fingerprint

    condensers
    diffraction patterns
    apertures
    illumination
    microscopes
    gratings (spectra)
    chutes
    radii

    ASJC Scopus subject areas

    • Atomic and Molecular Physics, and Optics

    Cite this

    Resolution of 90 nm (λ/5) in an optical transmission microscope with an annular condenser. / Vainrub, Arnold; Pustovyy, Oleg; Vodyanoy, Vitaly.

    In: Optics Letters, Vol. 31, No. 19, 01.10.2006, p. 2855-2857.

    Research output: Contribution to journalArticle

    Vainrub, Arnold ; Pustovyy, Oleg ; Vodyanoy, Vitaly. / Resolution of 90 nm (λ/5) in an optical transmission microscope with an annular condenser. In: Optics Letters. 2006 ; Vol. 31, No. 19. pp. 2855-2857.
    @article{d85098605a5249d2aa58256fe3ac7a34,
    title = "Resolution of 90 nm (λ/5) in an optical transmission microscope with an annular condenser",
    abstract = "Resolution of 90 nm was achieved with a research microscope simply by replacing the standard bright-field condenser with a homebuilt illumination system with a cardioid annular condenser. Diffraction gratings with 100 nm width lines as well as less than 100 nm size features of different-shaped objects were clearly visible on a calibrated microscope test slide. The resolution increase results from a known narrower diffraction pattern in coherent illumination for the annular aperture compared with the circular aperture. This explanation is supported by an excellent accord of calculated and measured diffraction patterns for a 50 nm radius disk.",
    author = "Arnold Vainrub and Oleg Pustovyy and Vitaly Vodyanoy",
    year = "2006",
    month = "10",
    day = "1",
    doi = "10.1364/OL.31.002855",
    language = "English (US)",
    volume = "31",
    pages = "2855--2857",
    journal = "Optics Letters",
    issn = "0146-9592",
    publisher = "The Optical Society",
    number = "19",

    }

    TY - JOUR

    T1 - Resolution of 90 nm (λ/5) in an optical transmission microscope with an annular condenser

    AU - Vainrub, Arnold

    AU - Pustovyy, Oleg

    AU - Vodyanoy, Vitaly

    PY - 2006/10/1

    Y1 - 2006/10/1

    N2 - Resolution of 90 nm was achieved with a research microscope simply by replacing the standard bright-field condenser with a homebuilt illumination system with a cardioid annular condenser. Diffraction gratings with 100 nm width lines as well as less than 100 nm size features of different-shaped objects were clearly visible on a calibrated microscope test slide. The resolution increase results from a known narrower diffraction pattern in coherent illumination for the annular aperture compared with the circular aperture. This explanation is supported by an excellent accord of calculated and measured diffraction patterns for a 50 nm radius disk.

    AB - Resolution of 90 nm was achieved with a research microscope simply by replacing the standard bright-field condenser with a homebuilt illumination system with a cardioid annular condenser. Diffraction gratings with 100 nm width lines as well as less than 100 nm size features of different-shaped objects were clearly visible on a calibrated microscope test slide. The resolution increase results from a known narrower diffraction pattern in coherent illumination for the annular aperture compared with the circular aperture. This explanation is supported by an excellent accord of calculated and measured diffraction patterns for a 50 nm radius disk.

    UR - http://www.scopus.com/inward/record.url?scp=33750157336&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=33750157336&partnerID=8YFLogxK

    U2 - 10.1364/OL.31.002855

    DO - 10.1364/OL.31.002855

    M3 - Article

    VL - 31

    SP - 2855

    EP - 2857

    JO - Optics Letters

    JF - Optics Letters

    SN - 0146-9592

    IS - 19

    ER -