Retinal OCT image enhancement via wavelet denoising

Shahab Chitchian, Markus A. Mayer, Adam R. Boretsky, Frederik J. Van-Kuijk, Massoud Motamedi

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

A denoising algorithm using double-density dual-tree complex wavelet transform is applied to two-frame OCT images of the retina to provide a comparable image quality in less acquisition time compared to commonly used multiple-frame averaging technique.

Original languageEnglish (US)
Title of host publicationBiomedical Optics, BIOMED 2012
StatePublished - 2012
EventBiomedical Optics, BIOMED 2012 - Miami, FL, United States
Duration: Apr 28 2012May 2 2012

Other

OtherBiomedical Optics, BIOMED 2012
CountryUnited States
CityMiami, FL
Period4/28/125/2/12

Fingerprint

retinal images
Image Enhancement
Wavelet Analysis
image enhancement
Retina
retina
wavelet analysis
acquisition

ASJC Scopus subject areas

  • Biotechnology
  • Atomic and Molecular Physics, and Optics

Cite this

Chitchian, S., Mayer, M. A., Boretsky, A. R., Van-Kuijk, F. J., & Motamedi, M. (2012). Retinal OCT image enhancement via wavelet denoising. In Biomedical Optics, BIOMED 2012

Retinal OCT image enhancement via wavelet denoising. / Chitchian, Shahab; Mayer, Markus A.; Boretsky, Adam R.; Van-Kuijk, Frederik J.; Motamedi, Massoud.

Biomedical Optics, BIOMED 2012. 2012.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Chitchian, S, Mayer, MA, Boretsky, AR, Van-Kuijk, FJ & Motamedi, M 2012, Retinal OCT image enhancement via wavelet denoising. in Biomedical Optics, BIOMED 2012. Biomedical Optics, BIOMED 2012, Miami, FL, United States, 4/28/12.
Chitchian S, Mayer MA, Boretsky AR, Van-Kuijk FJ, Motamedi M. Retinal OCT image enhancement via wavelet denoising. In Biomedical Optics, BIOMED 2012. 2012
Chitchian, Shahab ; Mayer, Markus A. ; Boretsky, Adam R. ; Van-Kuijk, Frederik J. ; Motamedi, Massoud. / Retinal OCT image enhancement via wavelet denoising. Biomedical Optics, BIOMED 2012. 2012.
@inproceedings{3f9acb904f084a70a155dc9113fd3d8c,
title = "Retinal OCT image enhancement via wavelet denoising",
abstract = "A denoising algorithm using double-density dual-tree complex wavelet transform is applied to two-frame OCT images of the retina to provide a comparable image quality in less acquisition time compared to commonly used multiple-frame averaging technique.",
author = "Shahab Chitchian and Mayer, {Markus A.} and Boretsky, {Adam R.} and Van-Kuijk, {Frederik J.} and Massoud Motamedi",
year = "2012",
language = "English (US)",
isbn = "9781557529428",
booktitle = "Biomedical Optics, BIOMED 2012",

}

TY - GEN

T1 - Retinal OCT image enhancement via wavelet denoising

AU - Chitchian, Shahab

AU - Mayer, Markus A.

AU - Boretsky, Adam R.

AU - Van-Kuijk, Frederik J.

AU - Motamedi, Massoud

PY - 2012

Y1 - 2012

N2 - A denoising algorithm using double-density dual-tree complex wavelet transform is applied to two-frame OCT images of the retina to provide a comparable image quality in less acquisition time compared to commonly used multiple-frame averaging technique.

AB - A denoising algorithm using double-density dual-tree complex wavelet transform is applied to two-frame OCT images of the retina to provide a comparable image quality in less acquisition time compared to commonly used multiple-frame averaging technique.

UR - http://www.scopus.com/inward/record.url?scp=84890695004&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84890695004&partnerID=8YFLogxK

M3 - Conference contribution

SN - 9781557529428

BT - Biomedical Optics, BIOMED 2012

ER -