Abstract

Purpose: To report robot-assisted stenting of a stenosis at the pulmonary artery anastomosis following lung transplantation, a rare complication that conveys poor prognosis even after surgical correction. Technique: The technique is illustrated in a 72-year-old man with end-stage lung disease who received a left single lung transplant. On postoperative day 54, he was evaluated for recurrent dyspnea on exertion that was due to a severe stenosis at the site of the pulmonary artery anastomosis. Balloon angioplasty was performed, and a 10-mm stent was deployed, with marked clinical improvement. Fourteen months later, he presented with recurrent symptoms due to in-stent restenosis. Multiple attempts at catheterization and balloon angioplasty of the stent failed. Due to the technical difficulty involved in maneuvering the balloon while maintaining stability, it was decided to repeat the angioplasty with the assistance of a Hansen Sensei remote robotic navigation system. The robotic arm markedly enhanced stability and facilitated successful navigation of the stented site. A 16-mm-diameter Wallstent was placed through the previously placed balloon-expandable stent and postdilated. Conclusion: A remote robotic catheter navigation system was able to assist stenting of an anastomotic pulmonary artery stenosis following failure of conventional interventional techniques.

Original languageEnglish (US)
Pages (from-to)612-616
Number of pages5
JournalJournal of Endovascular Therapy
Volume17
Issue number5
DOIs
StatePublished - Oct 2010
Externally publishedYes

Fingerprint

Lung Transplantation
Stents
Robotics
Balloon Angioplasty
Angioplasty
Catheterization
Dyspnea
Pulmonary Artery
Lung Diseases
Pathologic Constriction
Catheters
Transplants
Lung
Pulmonary Artery Stenosis

Keywords

  • Balloon angioplasty
  • Pulmonary artery
  • Remote robotic catheter navigation system
  • Stenosis
  • Stent

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Radiology Nuclear Medicine and imaging

Cite this

Lumsden, A. B., Anaya-Ayala, J. E., Birnbaum, I., Davies, M. G., Bismuth, J., Cheema, Z., ... Valderrabano, M. (2010). Robot-assisted stenting of a high-grade anastomotic pulmonary artery stenosis following single lung transplantation. Journal of Endovascular Therapy, 17(5), 612-616. https://doi.org/10.1583/10-3208R.1

Robot-assisted stenting of a high-grade anastomotic pulmonary artery stenosis following single lung transplantation. / Lumsden, Alan B.; Anaya-Ayala, Javier E.; Birnbaum, Itamar; Davies, Mark G.; Bismuth, Jean; Cheema, Zulfiqar; El Sayed, Hossam F.; Seethamraju, Harish; Loebe, Matthias; Valderrabano, Miguel.

In: Journal of Endovascular Therapy, Vol. 17, No. 5, 10.2010, p. 612-616.

Research output: Contribution to journalArticle

Lumsden, AB, Anaya-Ayala, JE, Birnbaum, I, Davies, MG, Bismuth, J, Cheema, Z, El Sayed, HF, Seethamraju, H, Loebe, M & Valderrabano, M 2010, 'Robot-assisted stenting of a high-grade anastomotic pulmonary artery stenosis following single lung transplantation', Journal of Endovascular Therapy, vol. 17, no. 5, pp. 612-616. https://doi.org/10.1583/10-3208R.1
Lumsden, Alan B. ; Anaya-Ayala, Javier E. ; Birnbaum, Itamar ; Davies, Mark G. ; Bismuth, Jean ; Cheema, Zulfiqar ; El Sayed, Hossam F. ; Seethamraju, Harish ; Loebe, Matthias ; Valderrabano, Miguel. / Robot-assisted stenting of a high-grade anastomotic pulmonary artery stenosis following single lung transplantation. In: Journal of Endovascular Therapy. 2010 ; Vol. 17, No. 5. pp. 612-616.
@article{fc6c518a29bc4a54845e772f87f6adb0,
title = "Robot-assisted stenting of a high-grade anastomotic pulmonary artery stenosis following single lung transplantation",
abstract = "Purpose: To report robot-assisted stenting of a stenosis at the pulmonary artery anastomosis following lung transplantation, a rare complication that conveys poor prognosis even after surgical correction. Technique: The technique is illustrated in a 72-year-old man with end-stage lung disease who received a left single lung transplant. On postoperative day 54, he was evaluated for recurrent dyspnea on exertion that was due to a severe stenosis at the site of the pulmonary artery anastomosis. Balloon angioplasty was performed, and a 10-mm stent was deployed, with marked clinical improvement. Fourteen months later, he presented with recurrent symptoms due to in-stent restenosis. Multiple attempts at catheterization and balloon angioplasty of the stent failed. Due to the technical difficulty involved in maneuvering the balloon while maintaining stability, it was decided to repeat the angioplasty with the assistance of a Hansen Sensei remote robotic navigation system. The robotic arm markedly enhanced stability and facilitated successful navigation of the stented site. A 16-mm-diameter Wallstent was placed through the previously placed balloon-expandable stent and postdilated. Conclusion: A remote robotic catheter navigation system was able to assist stenting of an anastomotic pulmonary artery stenosis following failure of conventional interventional techniques.",
keywords = "Balloon angioplasty, Pulmonary artery, Remote robotic catheter navigation system, Stenosis, Stent",
author = "Lumsden, {Alan B.} and Anaya-Ayala, {Javier E.} and Itamar Birnbaum and Davies, {Mark G.} and Jean Bismuth and Zulfiqar Cheema and {El Sayed}, {Hossam F.} and Harish Seethamraju and Matthias Loebe and Miguel Valderrabano",
year = "2010",
month = "10",
doi = "10.1583/10-3208R.1",
language = "English (US)",
volume = "17",
pages = "612--616",
journal = "Journal of Endovascular Therapy",
issn = "1526-6028",
publisher = "International Society of Endovascular Specialists",
number = "5",

}

TY - JOUR

T1 - Robot-assisted stenting of a high-grade anastomotic pulmonary artery stenosis following single lung transplantation

AU - Lumsden, Alan B.

AU - Anaya-Ayala, Javier E.

AU - Birnbaum, Itamar

AU - Davies, Mark G.

AU - Bismuth, Jean

AU - Cheema, Zulfiqar

AU - El Sayed, Hossam F.

AU - Seethamraju, Harish

AU - Loebe, Matthias

AU - Valderrabano, Miguel

PY - 2010/10

Y1 - 2010/10

N2 - Purpose: To report robot-assisted stenting of a stenosis at the pulmonary artery anastomosis following lung transplantation, a rare complication that conveys poor prognosis even after surgical correction. Technique: The technique is illustrated in a 72-year-old man with end-stage lung disease who received a left single lung transplant. On postoperative day 54, he was evaluated for recurrent dyspnea on exertion that was due to a severe stenosis at the site of the pulmonary artery anastomosis. Balloon angioplasty was performed, and a 10-mm stent was deployed, with marked clinical improvement. Fourteen months later, he presented with recurrent symptoms due to in-stent restenosis. Multiple attempts at catheterization and balloon angioplasty of the stent failed. Due to the technical difficulty involved in maneuvering the balloon while maintaining stability, it was decided to repeat the angioplasty with the assistance of a Hansen Sensei remote robotic navigation system. The robotic arm markedly enhanced stability and facilitated successful navigation of the stented site. A 16-mm-diameter Wallstent was placed through the previously placed balloon-expandable stent and postdilated. Conclusion: A remote robotic catheter navigation system was able to assist stenting of an anastomotic pulmonary artery stenosis following failure of conventional interventional techniques.

AB - Purpose: To report robot-assisted stenting of a stenosis at the pulmonary artery anastomosis following lung transplantation, a rare complication that conveys poor prognosis even after surgical correction. Technique: The technique is illustrated in a 72-year-old man with end-stage lung disease who received a left single lung transplant. On postoperative day 54, he was evaluated for recurrent dyspnea on exertion that was due to a severe stenosis at the site of the pulmonary artery anastomosis. Balloon angioplasty was performed, and a 10-mm stent was deployed, with marked clinical improvement. Fourteen months later, he presented with recurrent symptoms due to in-stent restenosis. Multiple attempts at catheterization and balloon angioplasty of the stent failed. Due to the technical difficulty involved in maneuvering the balloon while maintaining stability, it was decided to repeat the angioplasty with the assistance of a Hansen Sensei remote robotic navigation system. The robotic arm markedly enhanced stability and facilitated successful navigation of the stented site. A 16-mm-diameter Wallstent was placed through the previously placed balloon-expandable stent and postdilated. Conclusion: A remote robotic catheter navigation system was able to assist stenting of an anastomotic pulmonary artery stenosis following failure of conventional interventional techniques.

KW - Balloon angioplasty

KW - Pulmonary artery

KW - Remote robotic catheter navigation system

KW - Stenosis

KW - Stent

UR - http://www.scopus.com/inward/record.url?scp=77958602939&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77958602939&partnerID=8YFLogxK

U2 - 10.1583/10-3208R.1

DO - 10.1583/10-3208R.1

M3 - Article

VL - 17

SP - 612

EP - 616

JO - Journal of Endovascular Therapy

JF - Journal of Endovascular Therapy

SN - 1526-6028

IS - 5

ER -