Segmental spinal instrumentation with sublaminar wires

W. A. Herndon, A. Sullivan, David Yngve, R. H. Gross, G. Dreher

Research output: Contribution to journalArticle

36 Citations (Scopus)

Abstract

Fifty-eight patients who had scoliosis or kyphosis of varying etiologies were followed for a minimum of two years (average, forty-four months) after segmental spinal instrumentation using sublaminar wires. In eight (19 per cent) of the patients who had been operated on for scoliosis one or both rods broke. The average time that had elapsed before the breakage was discovered was twenty-three months. None of the patients in whom a rod had broken had had postoperative immobilization or a first-stage anterior fusion, and only one had had supplementary grafting with banked bone. Instrumentation to the pelvis was also associated with a greater incidence of broken rods. The use of supplementary grafting with banked bone or the use of postoperative immobilization significantly decreased the loss of postoperative correction. Preliminary anterior spinal fusion helped prevent breakage of rods but not loss of correction. It was concluded that postoperative immobilization and use of large amounts of supplementary bone graft lead to better results when using this implant system.

Original languageEnglish (US)
Pages (from-to)851-859
Number of pages9
JournalJournal of Bone and Joint Surgery - Series A
Volume69
Issue number6
StatePublished - 1987
Externally publishedYes

Fingerprint

Immobilization
Scoliosis
Bone and Bones
Spinal Fusion
Kyphosis
Pelvis
Transplants
Incidence

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine
  • Surgery

Cite this

Herndon, W. A., Sullivan, A., Yngve, D., Gross, R. H., & Dreher, G. (1987). Segmental spinal instrumentation with sublaminar wires. Journal of Bone and Joint Surgery - Series A, 69(6), 851-859.

Segmental spinal instrumentation with sublaminar wires. / Herndon, W. A.; Sullivan, A.; Yngve, David; Gross, R. H.; Dreher, G.

In: Journal of Bone and Joint Surgery - Series A, Vol. 69, No. 6, 1987, p. 851-859.

Research output: Contribution to journalArticle

Herndon, WA, Sullivan, A, Yngve, D, Gross, RH & Dreher, G 1987, 'Segmental spinal instrumentation with sublaminar wires', Journal of Bone and Joint Surgery - Series A, vol. 69, no. 6, pp. 851-859.
Herndon, W. A. ; Sullivan, A. ; Yngve, David ; Gross, R. H. ; Dreher, G. / Segmental spinal instrumentation with sublaminar wires. In: Journal of Bone and Joint Surgery - Series A. 1987 ; Vol. 69, No. 6. pp. 851-859.
@article{1240e6a8f25043d19cdc7fa3ae75c35f,
title = "Segmental spinal instrumentation with sublaminar wires",
abstract = "Fifty-eight patients who had scoliosis or kyphosis of varying etiologies were followed for a minimum of two years (average, forty-four months) after segmental spinal instrumentation using sublaminar wires. In eight (19 per cent) of the patients who had been operated on for scoliosis one or both rods broke. The average time that had elapsed before the breakage was discovered was twenty-three months. None of the patients in whom a rod had broken had had postoperative immobilization or a first-stage anterior fusion, and only one had had supplementary grafting with banked bone. Instrumentation to the pelvis was also associated with a greater incidence of broken rods. The use of supplementary grafting with banked bone or the use of postoperative immobilization significantly decreased the loss of postoperative correction. Preliminary anterior spinal fusion helped prevent breakage of rods but not loss of correction. It was concluded that postoperative immobilization and use of large amounts of supplementary bone graft lead to better results when using this implant system.",
author = "Herndon, {W. A.} and A. Sullivan and David Yngve and Gross, {R. H.} and G. Dreher",
year = "1987",
language = "English (US)",
volume = "69",
pages = "851--859",
journal = "Journal of Bone and Joint Surgery - American Volume",
issn = "0021-9355",
publisher = "Journal of Bone and Joint Surgery Inc.",
number = "6",

}

TY - JOUR

T1 - Segmental spinal instrumentation with sublaminar wires

AU - Herndon, W. A.

AU - Sullivan, A.

AU - Yngve, David

AU - Gross, R. H.

AU - Dreher, G.

PY - 1987

Y1 - 1987

N2 - Fifty-eight patients who had scoliosis or kyphosis of varying etiologies were followed for a minimum of two years (average, forty-four months) after segmental spinal instrumentation using sublaminar wires. In eight (19 per cent) of the patients who had been operated on for scoliosis one or both rods broke. The average time that had elapsed before the breakage was discovered was twenty-three months. None of the patients in whom a rod had broken had had postoperative immobilization or a first-stage anterior fusion, and only one had had supplementary grafting with banked bone. Instrumentation to the pelvis was also associated with a greater incidence of broken rods. The use of supplementary grafting with banked bone or the use of postoperative immobilization significantly decreased the loss of postoperative correction. Preliminary anterior spinal fusion helped prevent breakage of rods but not loss of correction. It was concluded that postoperative immobilization and use of large amounts of supplementary bone graft lead to better results when using this implant system.

AB - Fifty-eight patients who had scoliosis or kyphosis of varying etiologies were followed for a minimum of two years (average, forty-four months) after segmental spinal instrumentation using sublaminar wires. In eight (19 per cent) of the patients who had been operated on for scoliosis one or both rods broke. The average time that had elapsed before the breakage was discovered was twenty-three months. None of the patients in whom a rod had broken had had postoperative immobilization or a first-stage anterior fusion, and only one had had supplementary grafting with banked bone. Instrumentation to the pelvis was also associated with a greater incidence of broken rods. The use of supplementary grafting with banked bone or the use of postoperative immobilization significantly decreased the loss of postoperative correction. Preliminary anterior spinal fusion helped prevent breakage of rods but not loss of correction. It was concluded that postoperative immobilization and use of large amounts of supplementary bone graft lead to better results when using this implant system.

UR - http://www.scopus.com/inward/record.url?scp=0023638607&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0023638607&partnerID=8YFLogxK

M3 - Article

C2 - 3597498

AN - SCOPUS:0023638607

VL - 69

SP - 851

EP - 859

JO - Journal of Bone and Joint Surgery - American Volume

JF - Journal of Bone and Joint Surgery - American Volume

SN - 0021-9355

IS - 6

ER -