Sequential one-lung isolation using a double arndt bronchial blocker technique

William C. Culp, Michael Kinsky

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

One-lung ventilation and isolation can be performed using a double-lumen endotracheal tube or one of several alternative airway devices. We report a case in which sequential lung isolation was performed by placing two Arndt bronchial blockers through a single-lumen endotracheal tube. Traditional double-lumen tubes can be difficult to place and have potential complications that may be avoided by placing two Arndt blockers.

Original languageEnglish (US)
Pages (from-to)945-946
Number of pages2
JournalAnesthesia and Analgesia
Volume99
Issue number3
DOIs
StatePublished - Sep 2004

Fingerprint

One-Lung Ventilation
Equipment and Supplies
Lung

ASJC Scopus subject areas

  • Anesthesiology and Pain Medicine

Cite this

Sequential one-lung isolation using a double arndt bronchial blocker technique. / Culp, William C.; Kinsky, Michael.

In: Anesthesia and Analgesia, Vol. 99, No. 3, 09.2004, p. 945-946.

Research output: Contribution to journalArticle

@article{c657e51271ce4412913d772bb1dd7d13,
title = "Sequential one-lung isolation using a double arndt bronchial blocker technique",
abstract = "One-lung ventilation and isolation can be performed using a double-lumen endotracheal tube or one of several alternative airway devices. We report a case in which sequential lung isolation was performed by placing two Arndt bronchial blockers through a single-lumen endotracheal tube. Traditional double-lumen tubes can be difficult to place and have potential complications that may be avoided by placing two Arndt blockers.",
author = "Culp, {William C.} and Michael Kinsky",
year = "2004",
month = "9",
doi = "10.1213/01.ANE.0000132697.22933.8C",
language = "English (US)",
volume = "99",
pages = "945--946",
journal = "Anesthesia and Analgesia",
issn = "0003-2999",
publisher = "Lippincott Williams and Wilkins",
number = "3",

}

TY - JOUR

T1 - Sequential one-lung isolation using a double arndt bronchial blocker technique

AU - Culp, William C.

AU - Kinsky, Michael

PY - 2004/9

Y1 - 2004/9

N2 - One-lung ventilation and isolation can be performed using a double-lumen endotracheal tube or one of several alternative airway devices. We report a case in which sequential lung isolation was performed by placing two Arndt bronchial blockers through a single-lumen endotracheal tube. Traditional double-lumen tubes can be difficult to place and have potential complications that may be avoided by placing two Arndt blockers.

AB - One-lung ventilation and isolation can be performed using a double-lumen endotracheal tube or one of several alternative airway devices. We report a case in which sequential lung isolation was performed by placing two Arndt bronchial blockers through a single-lumen endotracheal tube. Traditional double-lumen tubes can be difficult to place and have potential complications that may be avoided by placing two Arndt blockers.

UR - http://www.scopus.com/inward/record.url?scp=4143143232&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=4143143232&partnerID=8YFLogxK

U2 - 10.1213/01.ANE.0000132697.22933.8C

DO - 10.1213/01.ANE.0000132697.22933.8C

M3 - Article

VL - 99

SP - 945

EP - 946

JO - Anesthesia and Analgesia

JF - Anesthesia and Analgesia

SN - 0003-2999

IS - 3

ER -