Abstract
We evaluated the feasibility, tolerability, and efficacy of a strategy for transaxillary artery intra-aortic balloon pump placement for extended mechanical circulatory support of patients with post-cardiotomy shock as a bridge to recovery. Patients requiring prolonged intra-aortic balloon pump support for postcardiotomy heart failure were identified. Intra-aortic balloon pump was tunneled through a 6-mm Dacron graft anastomosed to the right axillary artery. The intra-aortic balloon pump catheter is advanced under fluoroscopic guidance into the descending thoracic aorta. Three patients were transferred from outside facilities, requiring prolonged intra-aortic balloon pump support for postcardiotomy heart failure. Patients included a 54-year-old woman with occluded grafts and left ventricular thrombus after coronary artery bypass grafting, ejection fraction (EF) of 23.4% on dobutamine infusion, intra-aortic balloon pump support for 39 days, max daily ambulated distance of 1250 feet, and discharged home on day 51 on milrinone infusion; a 63-year-old man with kinked left internal mammary artery to left anterior descending artery graft (surgically repaired), multiple failed extubations requiring tracheostomy, EF of 15% on epinephrine and milrinone, intra-aortic balloon pump support for 43 days, max daily ambulated distance of 400 feet, and discharged home on day 54; and a 66-year-old man after redo coronary artery bypass grafting + carotid endarterectomy, with failure to wean off cardiopulmonary bypass requiring veno-arterial extracorporeal membrane oxygenator, EF of 20% on epinephrine and norepinephrine, intra-aortic balloon pump support for 41 days, max daily ambulated distance of 2800 feet, and discharged home on day 91. There were no infection, thromboembolic, cerebrovascular, bleeding, or intra-aortic balloon pump malpositioning/migration complications. We found that transaxillary artery intra-aortic balloon pump is well tolerated by patients and allows early ambulation and aggressive physical therapy in patients needing extended support. Duration of intra-aortic balloon pump support was up to 43 days with no complications.
| Original language | English (US) |
|---|---|
| Pages (from-to) | 472-478 |
| Number of pages | 7 |
| Journal | Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery |
| Volume | 12 |
| Issue number | 6 |
| DOIs | |
| State | Published - Nov 1 2017 |
| Externally published | Yes |
Keywords
- Axillary cannulation
- Bridge to mechanical circulatory support
- Bridge to recovery
- Intra-aortic balloon pump
ASJC Scopus subject areas
- Surgery
- Pulmonary and Respiratory Medicine
- Cardiology and Cardiovascular Medicine
Fingerprint
Dive into the research topics of 'The Axillary Intra-Aortic Balloon Pump as a Bridge to Recovery Allows Early Ambulation in Long-Term Use: Case Series and Literature Review'. Together they form a unique fingerprint.Cite this
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS