The pharmacokinetics of oxytocin as they apply to labor induction

R. L. Perry, A. J. Satin, W. H. Barth, S. Valtier, J. T. Cody, Gary Hankins

Research output: Contribution to journalArticle

9 Citations (Scopus)

Abstract

OBJECTIVE: Our purpose was to determine the relationship among plasma oxytocin levels, metabolic clearance rate of oxytocin, and uterine activity in gravid women undergoing labor induction. STUDY DESIGN: Ten women receiving oxytocin for labor induction and agreeing to participate had blood sampled before initiation of oxytocin and at different levels of uterine pressure. Samples were analyzed with 200 μl extracts from 1 ml of plasma with an oxytocin radioimmunoassay. The intraassay coefficient of variation was <3%. Sensitivity of the assay was 1.5 pg/ml. Pharmacokinetic parameters including plasma levels and metabolic clearance rates were calculated. Data were analyzed with the paired t test and linear and logistic regression. RESULTS: Mean oxytocin levels and metabolic clearance rates were 26.6 pg/ml and 7.97 ml/min. There was no correlation between changes in oxytocin level and metabolic clearance rate. Increases in infusion rates were correlated with increases in oxytocin levels (r = 0.71, p < 0.001). Cervical dilatation and uterine contraction pressures did not correlate with oxytocin levels. CONCLUSION: Peripheral plasma levels of oxytocin may not accurately reflect uterine activity or progress in labor. Plasma levels of oxytocin may merely reflect the rate of oxytocin infusion.

Original languageEnglish (US)
Pages (from-to)1590-1593
Number of pages4
JournalAmerican Journal of Obstetrics and Gynecology
Volume174
Issue number5
DOIs
StatePublished - 1996
Externally publishedYes

Fingerprint

Induced Labor
Oxytocin
Pharmacokinetics
Metabolic Clearance Rate
First Labor Stage
Pressure
Uterine Contraction
Radioimmunoassay
Linear Models

Keywords

  • labor induction
  • Oxytocin
  • pharmacokinetics

ASJC Scopus subject areas

  • Medicine(all)
  • Obstetrics and Gynecology

Cite this

Perry, R. L., Satin, A. J., Barth, W. H., Valtier, S., Cody, J. T., & Hankins, G. (1996). The pharmacokinetics of oxytocin as they apply to labor induction. American Journal of Obstetrics and Gynecology, 174(5), 1590-1593. https://doi.org/10.1016/S0002-9378(96)70611-7

The pharmacokinetics of oxytocin as they apply to labor induction. / Perry, R. L.; Satin, A. J.; Barth, W. H.; Valtier, S.; Cody, J. T.; Hankins, Gary.

In: American Journal of Obstetrics and Gynecology, Vol. 174, No. 5, 1996, p. 1590-1593.

Research output: Contribution to journalArticle

Perry, RL, Satin, AJ, Barth, WH, Valtier, S, Cody, JT & Hankins, G 1996, 'The pharmacokinetics of oxytocin as they apply to labor induction', American Journal of Obstetrics and Gynecology, vol. 174, no. 5, pp. 1590-1593. https://doi.org/10.1016/S0002-9378(96)70611-7
Perry, R. L. ; Satin, A. J. ; Barth, W. H. ; Valtier, S. ; Cody, J. T. ; Hankins, Gary. / The pharmacokinetics of oxytocin as they apply to labor induction. In: American Journal of Obstetrics and Gynecology. 1996 ; Vol. 174, No. 5. pp. 1590-1593.
@article{b1bc5ede30da4d8aa6443b4cf7087cd2,
title = "The pharmacokinetics of oxytocin as they apply to labor induction",
abstract = "OBJECTIVE: Our purpose was to determine the relationship among plasma oxytocin levels, metabolic clearance rate of oxytocin, and uterine activity in gravid women undergoing labor induction. STUDY DESIGN: Ten women receiving oxytocin for labor induction and agreeing to participate had blood sampled before initiation of oxytocin and at different levels of uterine pressure. Samples were analyzed with 200 μl extracts from 1 ml of plasma with an oxytocin radioimmunoassay. The intraassay coefficient of variation was <3{\%}. Sensitivity of the assay was 1.5 pg/ml. Pharmacokinetic parameters including plasma levels and metabolic clearance rates were calculated. Data were analyzed with the paired t test and linear and logistic regression. RESULTS: Mean oxytocin levels and metabolic clearance rates were 26.6 pg/ml and 7.97 ml/min. There was no correlation between changes in oxytocin level and metabolic clearance rate. Increases in infusion rates were correlated with increases in oxytocin levels (r = 0.71, p < 0.001). Cervical dilatation and uterine contraction pressures did not correlate with oxytocin levels. CONCLUSION: Peripheral plasma levels of oxytocin may not accurately reflect uterine activity or progress in labor. Plasma levels of oxytocin may merely reflect the rate of oxytocin infusion.",
keywords = "labor induction, Oxytocin, pharmacokinetics",
author = "Perry, {R. L.} and Satin, {A. J.} and Barth, {W. H.} and S. Valtier and Cody, {J. T.} and Gary Hankins",
year = "1996",
doi = "10.1016/S0002-9378(96)70611-7",
language = "English (US)",
volume = "174",
pages = "1590--1593",
journal = "American Journal of Obstetrics and Gynecology",
issn = "0002-9378",
publisher = "Mosby Inc.",
number = "5",

}

TY - JOUR

T1 - The pharmacokinetics of oxytocin as they apply to labor induction

AU - Perry, R. L.

AU - Satin, A. J.

AU - Barth, W. H.

AU - Valtier, S.

AU - Cody, J. T.

AU - Hankins, Gary

PY - 1996

Y1 - 1996

N2 - OBJECTIVE: Our purpose was to determine the relationship among plasma oxytocin levels, metabolic clearance rate of oxytocin, and uterine activity in gravid women undergoing labor induction. STUDY DESIGN: Ten women receiving oxytocin for labor induction and agreeing to participate had blood sampled before initiation of oxytocin and at different levels of uterine pressure. Samples were analyzed with 200 μl extracts from 1 ml of plasma with an oxytocin radioimmunoassay. The intraassay coefficient of variation was <3%. Sensitivity of the assay was 1.5 pg/ml. Pharmacokinetic parameters including plasma levels and metabolic clearance rates were calculated. Data were analyzed with the paired t test and linear and logistic regression. RESULTS: Mean oxytocin levels and metabolic clearance rates were 26.6 pg/ml and 7.97 ml/min. There was no correlation between changes in oxytocin level and metabolic clearance rate. Increases in infusion rates were correlated with increases in oxytocin levels (r = 0.71, p < 0.001). Cervical dilatation and uterine contraction pressures did not correlate with oxytocin levels. CONCLUSION: Peripheral plasma levels of oxytocin may not accurately reflect uterine activity or progress in labor. Plasma levels of oxytocin may merely reflect the rate of oxytocin infusion.

AB - OBJECTIVE: Our purpose was to determine the relationship among plasma oxytocin levels, metabolic clearance rate of oxytocin, and uterine activity in gravid women undergoing labor induction. STUDY DESIGN: Ten women receiving oxytocin for labor induction and agreeing to participate had blood sampled before initiation of oxytocin and at different levels of uterine pressure. Samples were analyzed with 200 μl extracts from 1 ml of plasma with an oxytocin radioimmunoassay. The intraassay coefficient of variation was <3%. Sensitivity of the assay was 1.5 pg/ml. Pharmacokinetic parameters including plasma levels and metabolic clearance rates were calculated. Data were analyzed with the paired t test and linear and logistic regression. RESULTS: Mean oxytocin levels and metabolic clearance rates were 26.6 pg/ml and 7.97 ml/min. There was no correlation between changes in oxytocin level and metabolic clearance rate. Increases in infusion rates were correlated with increases in oxytocin levels (r = 0.71, p < 0.001). Cervical dilatation and uterine contraction pressures did not correlate with oxytocin levels. CONCLUSION: Peripheral plasma levels of oxytocin may not accurately reflect uterine activity or progress in labor. Plasma levels of oxytocin may merely reflect the rate of oxytocin infusion.

KW - labor induction

KW - Oxytocin

KW - pharmacokinetics

UR - http://www.scopus.com/inward/record.url?scp=0029883454&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0029883454&partnerID=8YFLogxK

U2 - 10.1016/S0002-9378(96)70611-7

DO - 10.1016/S0002-9378(96)70611-7

M3 - Article

VL - 174

SP - 1590

EP - 1593

JO - American Journal of Obstetrics and Gynecology

JF - American Journal of Obstetrics and Gynecology

SN - 0002-9378

IS - 5

ER -