The use of a virtual three-dimensional model to evaluate the intraosseous space available for percutaneous screw fixation of acetabular fractures

Naftaly Attias, Ronald Lindsey, A. J. Starr, D. Borer, K. Bridges, J. A. Hipp

Research output: Contribution to journalArticle

43 Citations (Scopus)

Abstract

We created virtual three-dimensional reconstruction models from computed tomography scans obtained from patients with acetabular fractures. Virtual cylindrical implants were placed intraosseously in the anterior column, the posterior column and across the dome of the acetabulum. The maximum diameter which was entirely contained within the bone was determined for each position of the screw. In the same model, the cross-sectional diameters of the columns were measured and compared to the maximum diameter of the corresponding virtual implant. We found that the mean maximum diameter of virtual implant accommodated by the anterior columns was 6.4 mm and that the smallest diameter of the columns was larger than the maximum diameter of the equivalent virtual implant. This study suggests that the size of the screw used for percutaneous fixation of acetabular fractures should not be based solely on the measurement of cross-sectional diameter and that virtual three-dimensional reconstructions might be useful in pre-operative planning.

Original languageEnglish (US)
Pages (from-to)1520-1523
Number of pages4
JournalJournal of Bone and Joint Surgery - Series B
Volume87
Issue number11
DOIs
StatePublished - Nov 2005
Externally publishedYes

Fingerprint

Fracture Fixation
Acetabulum
Tomography
Bone and Bones

ASJC Scopus subject areas

  • Surgery
  • Orthopedics and Sports Medicine

Cite this

The use of a virtual three-dimensional model to evaluate the intraosseous space available for percutaneous screw fixation of acetabular fractures. / Attias, Naftaly; Lindsey, Ronald; Starr, A. J.; Borer, D.; Bridges, K.; Hipp, J. A.

In: Journal of Bone and Joint Surgery - Series B, Vol. 87, No. 11, 11.2005, p. 1520-1523.

Research output: Contribution to journalArticle

@article{c21ad426cd7b4f00b26c92c0a33729bc,
title = "The use of a virtual three-dimensional model to evaluate the intraosseous space available for percutaneous screw fixation of acetabular fractures",
abstract = "We created virtual three-dimensional reconstruction models from computed tomography scans obtained from patients with acetabular fractures. Virtual cylindrical implants were placed intraosseously in the anterior column, the posterior column and across the dome of the acetabulum. The maximum diameter which was entirely contained within the bone was determined for each position of the screw. In the same model, the cross-sectional diameters of the columns were measured and compared to the maximum diameter of the corresponding virtual implant. We found that the mean maximum diameter of virtual implant accommodated by the anterior columns was 6.4 mm and that the smallest diameter of the columns was larger than the maximum diameter of the equivalent virtual implant. This study suggests that the size of the screw used for percutaneous fixation of acetabular fractures should not be based solely on the measurement of cross-sectional diameter and that virtual three-dimensional reconstructions might be useful in pre-operative planning.",
author = "Naftaly Attias and Ronald Lindsey and Starr, {A. J.} and D. Borer and K. Bridges and Hipp, {J. A.}",
year = "2005",
month = "11",
doi = "10.1302/0301-620X.87B11.16614",
language = "English (US)",
volume = "87",
pages = "1520--1523",
journal = "Bone and Joint Journal",
issn = "2049-4394",
publisher = "British Editorial Society of Bone and Joint Surgery",
number = "11",

}

TY - JOUR

T1 - The use of a virtual three-dimensional model to evaluate the intraosseous space available for percutaneous screw fixation of acetabular fractures

AU - Attias, Naftaly

AU - Lindsey, Ronald

AU - Starr, A. J.

AU - Borer, D.

AU - Bridges, K.

AU - Hipp, J. A.

PY - 2005/11

Y1 - 2005/11

N2 - We created virtual three-dimensional reconstruction models from computed tomography scans obtained from patients with acetabular fractures. Virtual cylindrical implants were placed intraosseously in the anterior column, the posterior column and across the dome of the acetabulum. The maximum diameter which was entirely contained within the bone was determined for each position of the screw. In the same model, the cross-sectional diameters of the columns were measured and compared to the maximum diameter of the corresponding virtual implant. We found that the mean maximum diameter of virtual implant accommodated by the anterior columns was 6.4 mm and that the smallest diameter of the columns was larger than the maximum diameter of the equivalent virtual implant. This study suggests that the size of the screw used for percutaneous fixation of acetabular fractures should not be based solely on the measurement of cross-sectional diameter and that virtual three-dimensional reconstructions might be useful in pre-operative planning.

AB - We created virtual three-dimensional reconstruction models from computed tomography scans obtained from patients with acetabular fractures. Virtual cylindrical implants were placed intraosseously in the anterior column, the posterior column and across the dome of the acetabulum. The maximum diameter which was entirely contained within the bone was determined for each position of the screw. In the same model, the cross-sectional diameters of the columns were measured and compared to the maximum diameter of the corresponding virtual implant. We found that the mean maximum diameter of virtual implant accommodated by the anterior columns was 6.4 mm and that the smallest diameter of the columns was larger than the maximum diameter of the equivalent virtual implant. This study suggests that the size of the screw used for percutaneous fixation of acetabular fractures should not be based solely on the measurement of cross-sectional diameter and that virtual three-dimensional reconstructions might be useful in pre-operative planning.

UR - http://www.scopus.com/inward/record.url?scp=28444467708&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=28444467708&partnerID=8YFLogxK

U2 - 10.1302/0301-620X.87B11.16614