Skip to main navigation Skip to search Skip to main content

Using generative adversarial deep learning networks to synthesize cerebrovascular reactivity imaging from pre-acetazolamide arterial spin labeling in moyamoya disease

  • Guangming Zhu
  • , Bin Jiang
  • , Hui Chen
  • , Jeremy J. Heit
  • , Micah Etter
  • , G. Alex Hishaw
  • , Tobias D. Faizy
  • , Gary Steinberg
  • , Max Wintermark

Research output: Contribution to journalArticlepeer-review

Abstract

Background: Cerebrovascular reactivity (CVR) assesses vascular health in various brain conditions, but CVR measurement requires a challenge to cerebral perfusion such as the administration of acetazolamide(ACZ), thus limiting widespread use. We determined whether generative adversarial networks (GANs) can create CVR images from baseline pre-ACZ arterial spin labeling (ASL) MRI. Methods: This study included 203 Moyamoya cases with a total of 3248 pre- and post-ACZ ASL Cerebral Blood Flow (CBF) images. Reference CVRs were generated from these CBF slices. From this set, 2640 slices were used to train a Pixel-to-Pixel GAN consisting of a generator and discriminator network, with the remaining 608 slices reserved as a testing set. Following training, the pre-ACZ CBF in the testing set was introduced to the trained model to generate synthesized CVR. The quality of the synthesized CVR was evaluated with structural similarity index(SSI), spatial correlation coefficient(SCC), and the root mean squared error(RMSE), compared with reference CVR. The segmentations of the low CVR regions were compared using the Dice similarity coefficient (DSC). Reference and synthesized CVRs in single-slice and individual-hemisphere settings were reviewed to assess CVR status, with Cohen’s Kappa measuring consistency. Results: The mean SSIs of the CVR of training and testing sets were 0.943 ± 0.019 and 0.943 ± 0.020. The mean SCCs of the CVR of training and testing sets were 0.988 ± 0.009 and 0.987 ± 0.011. The mean RMSEs of the CVR are 0.077 ± 0.015 and 0.079 ± 0.018. Mean DSC of low CVR area of testing sets was 0.593 ± 0.128. Visual interpretation yielded Cohen’s Kappa values of 0.896 and 0.813 for the training and testing sets in the single-slice setting, and 0.781 and 0.730 in the individual-hemisphere setting. Conclusions: Synthesized CVR by GANs from baseline ASL without challenge may be a useful alternative in detecting vascular deficits in clinical applications when ACZ challenge is not feasible.

Original languageEnglish (US)
Pages (from-to)1251-1262
Number of pages12
JournalNeuroradiology
Volume67
Issue number5
DOIs
StatePublished - May 2025
Externally publishedYes

Keywords

  • Arterial spin labeling
  • Cerebral blood flow
  • Cerebrovascular reactivity
  • Deep learning
  • Generative adversarial networks

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Clinical Neurology
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Using generative adversarial deep learning networks to synthesize cerebrovascular reactivity imaging from pre-acetazolamide arterial spin labeling in moyamoya disease'. Together they form a unique fingerprint.

Cite this